胫动脉旁路术后术中荧光血管造影评估血管体概念的初步研究
这项前瞻性初步研究纳入40例Rutherford IV–VI期严重肢体缺血患者,在胫动脉旁路术前术后用术中荧光血管造影评估皮肤微循环。结果显示术后微循环参数显著改善,直接与间接血运重建血管体之间无显著差异,伤口愈合率相似,直接组愈合时间平均快2.5个月(p=.083)。
要点
- 胫动脉旁路术后全足微循环均改善,与血运重建的胫动脉无关。
- 直接与间接血运重建血管体的微循环改善无显著差异。
- 直接组伤口愈合时间平均快2.5个月,但差异未达统计学显著。
核心结论
- 胫动脉旁路术后全足微循环均改善,荧光血管造影是未来评估血管体概念的有前景工具。
研究设计与样本
- 前瞻性初步研究,纳入40例Rutherford IV–VI期严重肢体缺血患者,在胫动脉旁路术前术后评估。
- 大循环用踝肱指数测量,皮肤微循环用术中荧光血管造影评估。
- 比较直接与间接血运重建血管体的微循环变化,并进行临床随访比较伤口愈合率。
主要发现
- 术后累积微循环参数显著改善(ingress、ingress rate p<.001)。
- 每个足部血管体在血运重建后均观察到总体微循环改善,无论哪条胫动脉被血运重建。
- 直接与间接血运重建血管体的微循环改善无显著差异(差值DR-IR,ingress:1.69,95%CI 71.73-75.11;ingress rate:0.08,95%CI -12.91至13.07)。
- 两组伤口愈合率相似,直接组伤口愈合时间平均快2.5个月(p=.083)。
临床怎么用
- 胫动脉旁路术后微循环改善不局限于直接血管体,支持全足微循环评估。
- 术中荧光血管造影可用于评估血管体概念,但需更大样本研究验证。
局限性
- 本研究为初步研究,样本量40例,结果需未来更大规模研究证实。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: The "angiosome" concept as a model for decision making in revascularisation of patients with critical limb ischaemia (CLI) has been subject to lively discussion in recent years. The aim of this prospective pilot study was to use intra-operative fluorescence angiography to provide further data on the angiosome concept on the level of microcirculation after tibial bypass surgery. DESIGN, MATERIALS, AND METHODS: This was a prospective analysis of 40 patients presenting with CLI Rutherford stage IV to VI before and after tibial bypass surgery. The macrocirculation was measured by the ankle brachial index. Skin microcirculation was assessed by intra-operative fluorescence angiography. The alteration of microcirculation was compared in direct and indirect revascularised angiosomes. Clinical follow-up investigations were performed and the wound healing rate was compared between the different revascularisation methods. RESULTS: Cumulated microcirculation parameters showed a significant improvement after surgery (ingress, ingress rate p<.001). Likewise, general microcirculatory improvement was observed in each foot angiosome after revascularisation, regardless of the tibial artery revascularised. Furthermore, a comparison of the direct (DR) and the indirect revascularised (IR) angiosomes did not show a significant difference concerning the improvement of microcirculation (difference DR-IR, ingress: 1.69, 95% CI 71.73-75.11; ingress rate: 0.08, 95% CI -12.91 to 13.07). The wound healing rate was similar in both groups, although the time to wound healing was faster by on average 2.5 months in the DR group (p=.083). CONCLUSION: Microcirculatory improvement was seen over the whole foot after tibial bypass. Therefore, fluorescence angiography is a promising tool to evaluate the angiosome concept in future larger studies. Clinicaltrials.gov: NCT03012750.
引用
- Rother U, Lang W, Horch RE, et al. Pilot Assessment of the Angiosome Concept by Intra-operative Fluorescence Angiography After Tibial Bypass Surgery. Eur J Vasc Endovasc Surg. 2018. PMID: 29305093. doi:10.1016/j.ejvs.2017.11.024
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。