文献速递主动脉疾病

现成分支支架腔内修复破裂胸腹主动脉瘤的中期结果

Mid-term Outcomes of Endovascular Repair of Ruptured Thoraco-abdominal Aortic Aneurysms with Off the Shelf Branched Stent Grafts.
PubMed 文献 · Eur J Vasc Endovasc Surg · 2018-01-04

本研究评估了2011至2016年间使用现成(OTS)分支支架行急诊分支腔内修复(b-EVAR)破裂胸腹主动脉瘤(rTAAA)的中期结局与可行性。仅18%患者符合OTS装置的解剖使用说明,技术失败率36%,30天死亡率27%,脊髓缺血发生率为30%。结论认为该术式解剖适配性低但可行,适用于血流动力学稳定的患者,不稳定患者不适合。

要点

  • 急诊b-EVAR用OTS装置修复rTAAA可行,但仅18%患者符合解剖使用说明。
  • 技术失败率36%,30天死亡率27%,脊髓缺血发生率30%。
  • 分支通畅率1年87.5%、2年72.2%,总体生存18个月为75%。

核心结论

  • 急诊b-EVAR用OTS装置修复rTAAA可行,但解剖适配性低。
  • 经适当辅助操作,该术式可提供给多数血流动力学稳定的患者。
  • 耗时的复杂操作不适合不稳定患者,且成功率低于择期手术。

研究设计与样本

  • 回顾性纳入2011至2016年所有接受b-EVAR的rTAAA患者。
  • 共11例急诊b-EVAR(10例动脉瘤,1例慢性夹层),使用OTS分支支架。
  • 通过术前、术中及术后影像评估技术成功、结局及急诊条件下可行性。

主要发现

  • 仅18%患者符合OTS装置的解剖使用说明,主要违规为主动脉管腔小和靶血管闭塞。
  • 中位手术时间430分钟(IQR 395-629)。
  • 技术失败率36%,包括1例术中死亡、1例靶血管插管失败、1例Ia型内漏和1例III型内漏。
  • 30天死亡率27%,脊髓缺血4例(30%),其中2例完全恢复。
  • 中位临床随访15个月(IQR 7-39),中位临床随访指数(FUI)0.65(0.32-0.95)。

临床怎么用

  • 急诊b-EVAR用OTS装置可作为血流动力学稳定rTAAA患者的治疗选择。
  • 需准备辅助操作以应对解剖不适配,并告知后期可能需再干预。
  • 不稳定患者不宜采用此耗时复杂术式。

局限性

  • 样本量小(11例),结果需更大规模研究和更长随访确认。
  • 仅18%患者符合OTS装置解剖使用说明,推广受限。
  • 随访时间有限,中位临床随访指数0.65。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To assess the mid-term outcomes and feasibility of branched endovascular repair (b-EVAR) of ruptured thoracoabdominal aortic aneurysms (rTAAAs). METHODS: All patients undergoing b-EVAR of rTAAAs between 2011 and 2016 were included. Pre-, intra and postoperative imaging was reviewed to assess technical success, outcomes, and feasibility of b-EVAR in the emergent setting. RESULTS: Eleven emergency b-EVAR of rTAAAs (10 aneurysms and 1 chronic dissection) were performed using off-the-shelf (OTS) branched stentgrafts. Only 18% of patients complied to the anatomical instruction-for-use of the OTS device; a small aortic lumen and occluded target vessels were the main violations. Median operative time was 430 (IQR 395-629) minutes. Technical failure was 36% including one intraoperative death, one target vessel catheterization failure, one type Ia and one type III endoleak. Thirty-day mortality was 27%. Only early re-intervention was for the type Ia endoleak. Spinal cord ischemia occurred in 4 patients (30%), of which 2 recovered completely. Median clinical follow-up were 15 (IQR 7-39) months respectively. The median clinical follow-up index (FUI) was 0.65 (0.32-0.95). Overall survival was 75 ± 21.7% at 18 months. Four branch occlusions occurred; one renal stent occlusion led to permanent hemodialysis. Branch patency was 87.5 ± 8.3% and 72.2 ± 12% at 1 and 2 years, respectively. One stentgraft migrated but no late major endoleak occurred. CONCLUSION: Emergency b-EVAR of rTAAA with OTS device is feasible despite a low anatomical suitability. With proper adjunctive procedures, it can be offered to most hemodynamically stable patients. These time-consuming complex procedures are not suitable for unstable patients. Often the procedure is done as life-saving in the emergency setting and reinterventions may be needed later. Consequently, the success rates are lower than in the elective setting. These results need to be confirmed by larger studies and longer follow-up.

来源:Eur J Vasc Endovasc Surg,查看原文。版权归原作者所有。

引用

  1. Hongku K, Sonesson B, Björses K, et al. Mid-term Outcomes of Endovascular Repair of Ruptured Thoraco-abdominal Aortic Aneurysms with Off the Shelf Branched Stent Grafts. Eur J Vasc Endovasc Surg. 2018. PMID: 29306626. doi:10.1016/j.ejvs.2017.11.021

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。