文献速递主动脉疾病内脏/肾动脉与血管畸形

LifeStream球囊扩张覆膜支架在开窗/分支胸腹主动脉腔内修复中的初步结果

Preliminary Outcomes of the LifeStream Balloon-Expandable Covered Stent in Fenestrated and Branched Thoracoabdominal Endovascular Repairs.
PubMed 文献 · J Endovasc Ther · 2018-01-09

单中心回顾性研究纳入18例胸腹主动脉瘤患者,使用Zenith开窗/分支支架联合43枚LifeStream球囊扩张覆膜支架桥接内脏动脉。技术成功率为100%,12个月通畅率100%,但开窗组出现较高比例(22%开窗)的IIIc型内漏,经近端裸支架再衬后解决。

要点

  • LifeStream支架在胸腹主动脉开窗/分支修复中12个月通畅率达100%。
  • 开窗组IIIc型内漏发生率为22%(7/32开窗),分支组无IIIc内漏。
  • 近端裸支架再衬可有效解决IIIc内漏,后续预防性再衬后无内漏。

核心结论

  • LifeStream球囊扩张覆膜支架在胸腹主动脉瘤开窗/分支腔内修复中表现出良好的通畅性,但IIIc型内漏发生率意外偏高,可通过近端裸支架再衬解决。

研究设计与样本

  • 单中心回顾性研究,2015年3月至2017年1月连续纳入18例胸腹主动脉瘤患者(中位年龄74.7岁,14例男性),共使用43枚LifeStream球囊扩张覆膜支架桥接11条腹腔干、8条肠系膜上动脉和24条肾动脉(32个开窗和11个分支)。

主要发现

  • 支架输送和释放技术成功率为100%。
  • 30天内5例患者出现开窗周围IIIc型内漏,涉及7/32(22%)个开窗,分支组无IIIc内漏。
  • 4例患者接受二次腔内再干预,在开窗移行区近端用裸球囊扩张支架再衬,1年随访时内漏完全消失;1例拒绝再干预。
  • 最后4例开窗支架预防性使用开窗周围裸支架再衬,影像学未见IIIc型内漏。
  • 中位随访14.1个月(四分位距11-22个月),LifeStream支架12个月通畅率为100%。

关键数值与推荐

  • 12个月LifeStream支架通畅率为100%。
  • IIIc型内漏发生率为22%(7/32开窗)。

临床怎么用

  • 对于胸腹主动脉瘤开窗/分支腔内修复,使用LifeStream球囊扩张覆膜支架桥接内脏动脉时需警惕IIIc型内漏,可考虑术中预防性近端裸支架再衬以改善开窗周围密封。

局限性

  • 单中心初步经验,样本量小(18例),随访时间有限(中位14.1个月),结论需更大规模研究验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To evaluate the 1-year outcomes of thoracoabdominal aortic aneurysm (TAAA) repair using fenestrated and branched stent-grafts and a novel balloon-expandable covered stent. METHODS: Between March 2015 and January 2017, 18 patients (median age 74.7 years; 14 men) received 43 LifeStream balloon-expandable covered stents in conjunction with Zenith fenestrated/branched stent-grafts to bridge 11 celiac trunks, 8 superior mesenteric arteries, and 24 renal arteries (total 32 fenestrations and 11 branches). RESULTS: Stent delivery and deployment was successful in all cases. At 30 days, 5 patients presented with perifenestration endoleaks (type IIIc) secondary to inadequate sealing of the LifeStream covered stent in 7 (22%) of 32 fenestrations. No type IIIc endoleaks were reported in the branched cases. Four patients had a secondary endovascular reintervention with proximal relining by means of a bare balloon-expandable stent at the perifenestration transition area, with complete resolution of the endoleak at 1-year follow-up. One patient refused reintervention. The last 4 fenestrated stent-grafts of this series had prophylactic perifenestration bare stent relining with no evidence of type IIIc endoleaks at imaging. At a median follow-up of 14.1 months (interquartile range 11, 22), the 12-month LifeStream patency rate was 100%. CONCLUSION: This single-center preliminary experience with the LifeStream balloon-expandable covered stent in fenestrated/branched stent-grafts for TAAA repairs demonstrated good patency; however, an unexpectedly high rate of type IIIc endoleaks was observed. These endoleaks were resolved with reintervention or during the index procedure by proximal relining with a bare balloon-expandable stent, achieving adequate perifenestration sealing.

来源:J Endovasc Ther,查看原文。版权归原作者所有。

引用

  1. Bertoglio L, Loschi D, Cambiaghi T, et al. Preliminary Outcomes of the LifeStream Balloon-Expandable Covered Stent in Fenestrated and Branched Thoracoabdominal Endovascular Repairs. J Endovasc Ther. 2018. PMID: 29313455. doi:10.1177/1526602817752449

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。