文献速递主动脉疾病

EVAS术后近端I型内漏的发生与分类:Nellix™装置分析

Editor's Choice - Occurrence and Classification of Proximal Type I Endoleaks After EndoVascular Aneurysm Sealing Using the Nellix™ Device.
PubMed 文献 · Eur J Vasc Endovasc Surg · 2017-10-28

该研究分析了15个中心1851例接受Nellix™ EVAS治疗的患者,中位随访494±283天,近端内漏发生率为3.1%(早期1.5%,晚期1.7%)。84%的病例超出原始IFU、96%超出当前 refined IFU。低支架定位是最可能原因(44.6%)。47%的病例接受栓塞或近端延伸治疗,技术成功率97%。

要点

  • EVAS术后近端内漏总发生率为3.1%,早期(30天内)为1.5%。
  • 绝大多数近端内漏与超适应证使用相关(84%超出原始IFU,96%超出当前IFU)。
  • 低支架定位是近端内漏的最常见原因(44.6%)。

核心结论

  • EVAS术后近端内漏总发生率为3.1%,平均随访16个月,其中1.5%发生在30天内。
  • 近端内漏的发生与患者选择和支架定位相关。
  • 早期发现和分类对于避免瘤囊破裂至关重要。

研究设计与样本

  • 共1851例患者接受EVAS治疗,中位随访494±283天。
  • 58例(3.1%)出现近端内漏,由核心实验室分析CT扫描,并通过共识会议讨论分类。

主要发现

  • 58例近端内漏中,早期1.5%,晚期1.7%。
  • 84%的58例患者超出原始IFU,96%超出当前 refined IFU。
  • 低支架定位是最可能原因,占44.6%;恶劣解剖占16.1%;两者结合占33.9%。
  • 47%的病例接受栓塞或近端延伸治疗,技术成功率为97%。

临床怎么用

  • EVAS术后应密切监测近端内漏,尤其关注早期(30天内)发生。
  • 严格遵循IFU选择患者,并注意支架定位以避免低支架置入。
  • 对近端内漏可采用栓塞或近端延伸治疗,技术成功率高。

局限性

  • 研究为回顾性设计,可能存在选择偏倚。
  • 随访时间中位约16个月,长期结果未报告。
  • 近端内漏例数较少(58例),部分亚组分析受限。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE/BACKGROUND: Proximal type I endoleaks are associated with abdominal aortic aneurysm (AAA) growth and rupture and necessitate repair. The Nellix™ EndoVascular Aneurysm Sealing (EVAS) system is a unique approach to AAA repair, where the appearance and treatment of endoleaks is also different. This study aimed to analyse and categorise proximal endoleaks in an EVAS treated cohort. METHODS: All patients, treated from February 2013 to December 2015, in 15 experienced EVAS centres, presenting with proximal endoleak were included. Computed tomography scans were analysed by a core laboratory. A consensus meeting was organised to discuss and qualify each case for selection, technical aspects, and possible causes of the endoleak. Endoleaks were classified using a novel classification system for EVAS. RESULTS: During the study period 1851 patients were treated using EVAS at 15 centres and followed for a median of 494 ± 283 days. Among these, 58 cases (3.1%) developed a proximal endoleak (1.5% early and 1.7% late); of these, 84% of 58 patients were treated outside the original and 96% outside the current, refined, instructions for use. Low stent positioning was the most likely cause in 44.6%, a hostile anatomy in 16.1%, and a combination of both in 33.9%. Treatment, by embolisation or proximal extension, was performed in 47% of cases, with a technical success of 97%. CONCLUSION: The overall incidence of proximal endoleak after EVAS is 3.1% after a mean follow-up period of 16 months, with 1.5% occurring within 30 days. Their occurrence is related to patient selection and stent positioning. Early detection and classification is crucial to avoid the potential of sac rupture.

来源:Eur J Vasc Endovasc Surg,查看原文。版权归原作者所有。

引用

  1. van den Ham LH, Holden A, Savlovskis J, et al. Editor's Choice - Occurrence and Classification of Proximal Type I Endoleaks After EndoVascular Aneurysm Sealing Using the Nellix™ Device. Eur J Vasc Endovasc Surg. 2017. PMID: 29089283. doi:10.1016/j.ejvs.2017.09.016

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。