TEVAR术后逆性A型夹层与支架移植物诱发新发破口的发生率及危险因素
分析显示近端裸支架与RTAD发生率无关,而支架连接杆和支架长度<165 mm增加RTAD和SINE风险。
要点
- 近端裸支架不增加RTAD发生率。
- 支架连接杆和长度<165 mm与SINE及RTAD风险升高相关。
- 吸烟、高血压、马凡综合征及慢性期TEVAR与SINE发生相关。
核心结论
- 近端裸支架的存在与较高的RTAD率无关。
- 使用带连接杆且长度<165 mm的支架移植物增加TEVAR术后RTAD和SINE风险。
研究设计与样本
- 53例患者发生59次SINE,比较近端裸支架组与非近端裸支架组及RTAD/SINE组与非RTAD/非SINE组。
主要发现
- 近端裸支架组与非近端裸支架组RTAD发生率无显著差异。
- 较大的oversizing ratio与较高的远端SINE率相关。
- 吸烟、高血压、马凡综合征及慢性期TEVAR患者SINE更常见,复杂夹层病例中较少见。
- SINE的器械相关因素包括带连接杆的支架移植物和支架长度<165 mm。
- 多变量分析中支架长度<165 mm增加整体近端和远端SINE发生率。
关键数值与推荐
- 支架长度<165 mm在多元分析中增加近端和远端SINE发生率。
- 带连接杆的支架移植物与SINE风险相关。
临床怎么用
- TEVAR术前应评估支架长度,避免使用<165 mm的支架移植物以降低SINE和RTAD风险。
- 对于吸烟、高血压、马凡综合征及慢性期TEVAR患者,应加强术后影像随访监测SINE。
局限性
- 随访时间0-6年,平均2.6年,可能低估远期并发症。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: Stent graft (SG)-induced new entry (SINE) and retrograde type A dissection (RTAD) are serious device-related complications occurring after thoracic endovascular aortic repair (TEVAR) for Stanford type B aortic dissection (TBAD) and may lead to endograft-related complications including retrograde dissection and death. The purpose of this study was to investigate the incidence and risk factors for the development of RTAD and SINE after TEVAR for TBAD and to identify the complications associated with this. METHODS: From April 2005 to October 2013, there were 997 patients who underwent TEVAR for TBAD; 852 were followed up (0-6 years; mean, 2.6 years), and 59 SINEs developed in 53 patients. The oversizing ratio and incidence of RTAD and SINE were compared between proximal bare stent (PBS) and non-PBS groups and RTAD and SINE and non-RTAD and non-SINE groups. The baseline characteristics and SG configurational factors potentially affecting both RTAD and distal SINE were analyzed. RESULTS: There was no significant difference between PBS and non-PBS groups in the incidence of RTAD. A greater oversizing ratio was related to a higher distal SINE rate. SINE was seen more frequently in smokers and in patients with hypertension, Marfan syndrome, and TEVAR in the chronic phase and less frequently in complicated dissection cases. Device-related factors for SINE were SG with a connecting bar and SG length <165 mm. The SG length <165 mm increased the overall proximal and distal SINE incidence in multivariate analysis. CONCLUSIONS: The presence of a PBS is not associated with a higher RTAD rate, whereas the use of an SG with a connecting bar and length <165 mm increases the risk of RTAD and SINE after TEVAR.
引用
- Ma T, Dong ZH, Fu WG, et al. Incidence and risk factors for retrograde type A dissection and stent graft-induced new entry after thoracic endovascular aortic repair. J Vasc Surg. 2017. PMID: 29097043. doi:10.1016/j.jvs.2017.08.070
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。