近端桡动脉动静脉瘘用于血液透析血管通路的12年经验
该研究回顾性分析了12年间1396例近端桡动脉动静脉瘘(PRA-AVF)患者,评估其通畅率、窃血综合征风险及生存情况。结果显示12个月和24个月累积通畅率分别为93%和91%,需干预的透析相关窃血综合征(DASS)发生率为2.8%,其中85%为糖尿病患者。
要点
- PRA-AVF提供良好的功能通畅率,24个月累积通畅率达91%。
- 需干预的DASS发生率低(2.8%),多发生于糖尿病患者。
- 女性、肥胖和年轻年龄是累积通畅率的不良因素。
核心结论
- PRA-AVF具有优异的功能通畅率和较低的透析相关窃血综合征风险。
研究设计与样本
- 回顾性分析12年期间连续接受PRA-AVF的1396例患者,术前均行超声血管定位。
主要发现
- 平均年龄59岁(标准差±15.9),女性717例(51%),糖尿病819例(59%),肥胖394例(28%)。
- 12个月和24个月的一期、一期辅助和累积通畅率分别为60%、90%、93%和47%、86%、91%。
- 需干预的DASS发生于39例(2.8%),其中85%为糖尿病患者;自发性DASS 15例(1.1%),球囊血管成形术后DASS 24例(1.7%)。
- 女性(风险比1.90,95%CI 1.37-2.65)、肥胖(风险比1.92,95%CI 1.40-2.65)和年轻年龄对累积通畅率有负面影响。
- 400例需行转位手术,其中189例(47%)分两阶段完成。
关键数值与推荐
- 为恢复手部灌注并保留AVF,常用手术包括束带术和流出支结扎或弹簧圈栓塞以减少通路流量。
- 限制血管成形术球囊尺寸可避免后期罕见的血管成形术诱导的DASS事件。
临床怎么用
- PRA-AVF可作为血液透析血管通路的优选方案,尤其适用于肘部静脉流出道条件广泛的患者。
- 对于糖尿病患者,应警惕DASS风险,术后密切监测手部缺血表现。
- 在行PRA-AVF吻合口球囊血管成形术时,应限制球囊尺寸以降低DASS风险。
局限性
- 回顾性单中心研究,可能存在选择偏倚。
- 随访时间范围大(0.7-127个月,中位25个月),部分患者随访时间较短。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: This study reviewed our experience with proximal radial artery-based arteriovenous fistulas (PRA-AVFs) for hemodialysis vascular access, evaluating characteristics of the patients, functional patency, risk of steal syndrome, survival of the patient, and technical considerations. METHODS: We retrospectively analyzed our database of consecutive patients, identifying those individuals with a PRA-AVF created during a 12-year period. In addition to physical examination, all patients underwent ultrasound vessel mapping by the operating surgeon, identifying the PRA-AVF configuration and outflow target most likely to succeed. RESULTS: PRA-AVFs were created in 1396 individuals during the 12-year study period. The mean age was 59 years (standard deviation, ±15.9 years); 717 (51%) patients were women, 819 (59%) were diabetic, and 394 (28%) were obese. A transposition procedure was required in 400 patients, and 189 (47%) of these were completed in two-staged operations. Preoperative characteristics with a negative impact on PRA-AVF cumulative patency included female gender (hazard ratio, 1.90; 95% confidence interval, 1.37-2.65), obesity (hazard ratio, 1.92; 95% confidence interval, 1.40-2.65), and younger age. Dialysis-associated steal syndrome (DASS) requiring an intervention occurred in 39 (2.8%) patients, and 85% of these were diabetic. The most common procedures required to restore hand perfusion while preserving the AVF were banding and outflow branch ligation or coil occlusion to decrease access flow. DASS emerged spontaneously in 15 (1.1%) of the patients, and 24 (1.7%) individuals developed hand ischemia requiring intervention after fistulography with balloon angioplasty of the PRA-AVF anastomosis during the first years of the study period. Limiting angioplasty balloon size for such patients avoided these uncommon angioplasty-induced DASS events in later years. Primary, primary assisted, and cumulative (secondary) patency rates were 60%, 90%, and 93% at 12 months and 47%, 86%, and 91% at 24 months, respectively. Follow-up was 0.7 to 127 months (median, 25 months). CONCLUSIONS: PRA-AVFs offer excellent functional patency with low risk of dialysis access-related steal syndrome. The antecubital site has a wide range of venous outflow options for both direct PRA-AVFs and transposition procedures.
引用
- Jennings WC, Mallios A, Mushtaq N, et al. Proximal radial artery arteriovenous fistula for hemodialysis vascular access. J Vasc Surg. 2017. PMID: 28912005. doi:10.1016/j.jvs.2017.06.114
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。