分支型主动脉内移植物保留盆腔循环修复近端吻合口假性动脉瘤的新应用
本文报告一例71岁男性,1999年因主髂动脉闭塞性疾病行主双股动脉旁路术,后于主动脉吻合口处发生8.8 cm假性动脉瘤。采用Cook Zenith分支型内移植物(24×80 mm主体,8×15 mm后分支)经右股动脉入路,结合左肱动脉抓捕预置导丝,将Bard Fluency 10×10 mm覆膜支架送入右髂总动脉,分支近端以Boston Scientific Express 8×17 mm支架加固。术后5天出院,1个月CTA显示旁路血管及分支移植物通畅、假性动脉瘤被隔绝。
要点
- 分支型主动脉内移植物可微创修复主双股动脉旁路近端吻合口假性动脉瘤。
- 该技术能同时保留盆腔血流和下肢灌注,避免开放手术相关风险。
- 术后1个月CTA证实旁路血管、分支移植物通畅且假性动脉瘤完全隔绝。
核心结论
- 分支型内移植物可用于主双股动脉旁路近端吻合口假性动脉瘤的微创修复,同时保留盆腔循环和下肢灌注。
研究设计与样本
- 单例病例报告:71岁男性,既往主双股动脉旁路术后发生8.8 cm主动脉吻合口假性动脉瘤。
主要发现
- 采用Cook Zenith分支型内移植物(主体24×80 mm,后分支8×15 mm)经右股动脉入路,左肱动脉抓捕预置导丝,分支内送入Bard Fluency 10×10 mm覆膜支架至右髂总动脉,近端以Boston Scientific Express 8×17 mm支架加固。
- 术后5天出院,1个月CTA显示主双股动脉旁路、分支移植物通畅,假性动脉瘤被隔绝。
临床怎么用
- 对于主双股动脉旁路术后近端吻合口假性动脉瘤且需保留盆腔血流的患者,可考虑分支型主动脉内移植物行微创修复。
局限性
- 单例病例报告,缺乏长期随访和大样本验证,技术可推广性需进一步研究。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Endovascular repair of a proximal anastomotic pseudoaneurysm (APSA) of an end-to-side aortobifemoral bypass (ABF) can lead to pelvic ischemia. We present a novel application of branched aortic endograft to repair such pseudoaneurysm while preserving flow into the ABF and native aortoiliac system. METHODS: A 71-year-old male with history of aortoiliac occlusive disease resulting in lifestyle limiting claudication was treated with an aortobifemoral bypass in 1999. The patient developed an 8.8 cm pseudoaneurysm at the aortic anastomosis. CTA demonstrated patent right common and internal iliac arteries with an occluded right external iliac artery and occluded left common and external iliac arteries. RESULTS: A 24 × 80 mm endograft with an 8 × 15 mm posterior branch based on the Cook Zenith device (Bloomington, IN) was delivered via a right femoral artery exposure. The preloaded wire of the main body was snared via left brachial access. A 10F sheath was advanced into the side branch of the graft to deliver a 10 × 10-mm Bard Fluency (Covington, Georgia) stent graft into the right common iliac artery. The branch was reinforced proximally with an 8 × 17 mm Boston Scientific Express (Marlborough, MA) stent. The patient was discharged after 5 days. At 1 month, CTA demonstrated patent ABF, patent branch graft into the pelvis, and exclusion of the pseudoaneurysm. CONCLUSIONS: Branch grafts can provide minimally invasive revision of a failing ABF, in this case an APSA, while preserving pelvic circulation and lower extremity perfusion.
引用
- Miler R, Kang J, Sowa P, et al. Novel Application of Branched Endograft for Preservation of Pelvic Circulation. Ann Vasc Surg. 2017. PMID: 28893709. doi:10.1016/j.avsg.2017.08.042
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。