文献速递主动脉疾病血液透析通路

亚洲人群EVAR经皮与外科入路后股总动脉口径变化

Common Femoral Artery Caliber Changes after Percutaneous versus Surgical Access in Endovascular Aneurysm Repair in the Asian Population.
PubMed 文献 · Ann Vasc Surg · 2017-09-22

两组总体CFA ID变化无显著差异(-0.12±1.05 mm vs -0.10±0.81 mm,P=0.36),各组内术前术后亦无显著变化。

要点

  • PEVAR与SEVAR组总体CFA ID变化无显著差异(P=0.36)
  • PEVAR组术前术后CFA ID无显著变化(P=0.34)
  • SEVAR组术前术后CFA ID无显著变化(P=0.15)

核心结论

  • PEVAR与SEVAR组股总动脉口径变化无显著差异。
  • 两组内股总动脉口径均无显著变化。

研究设计与样本

  • 在CT主动脉造影上于3个固定水平测量股总动脉内径(CFA ID),比较术前与术后。
  • 按腹股沟分为PEVAR组和SEVAR组,独立样本t检验比较总体CFA ID变化,配对样本t检验评估组内变化,P<0.05为显著。

主要发现

  • PEVAR与SEVAR组总体CFA ID变化无显著差异(-0.12±1.05 mm vs -0.10±0.81 mm,P=0.36)。
  • PEVAR组CFA ID术前7.92±1.23 mm、术后7.80±1.38 mm,无显著变化(P=0.34)。
  • SEVAR组CFA ID术前7.47±1.44 mm、术后7.36±1.64 mm,无显著变化(P=0.15)。
  • 两组人口学特征无显著差异,除鞘管尺寸和CT主动脉造影随访时间外。

临床怎么用

  • 在亚洲人群中,EVAR经皮或外科入路后股总动脉口径未见显著改变。
  • 选择入路方式时,股总动脉口径变化可能不是主要考量因素。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Western studies showed vascular caliber changes post-endovascular aneurysm repair (EVAR). This study aims to evaluate for postoperative changes of the common femoral artery inner diameter (CFA ID) in the Asian population. METHODS: From January 2011 to June 2016, 202 patients who underwent EVAR were reviewed. CFA IDs were evaluated at 3 fixed levels on computed tomography (CT) aortograms. Preoperative and postoperative measurements were compared. Per-groin analysis was carried out after division into percutaneous access endovascular aneurysm repair (PEVAR) and surgical access endovascular aneurysm repair (SEVAR) groups. Independent sample t-test compared for differences in overall CFA ID changes between PEVAR and SEVAR groups. Paired sample t-test evaluated CFA ID changes in each group. P value < 0.05 was considered significant. RESULTS: One hundred and twenty patients were included, with 200 groins subsequently analyzed. The PEVAR and SEVAR groups have no significant demographic differences, except in sheath size and duration of CT aortogram follow-up. No significant differences in overall CFA ID changes comparing PEVAR and SEVAR groups (-0.12 ± 1.05 mm, -0.10 ± 0.81 mm, P = 0.36). No significant overall CFA ID changes in both PEVAR (7.92 ± 1.23 mm, 7.80 ± 1.38 mm, P = 0.34) and SEVAR groups (7.47 ± 1.44 mm, 7.36 ± 1.64 mm, P = 0.15). CONCLUSIONS: No significant differences in CFA caliber changes comparing PEVAR and SEVAR. No significant CFA caliber changes in either group.

来源:Ann Vasc Surg,查看原文。版权归原作者所有。

引用

  1. Ong DY, Tan GWL, Chan MS, et al. Common Femoral Artery Caliber Changes after Percutaneous versus Surgical Access in Endovascular Aneurysm Repair in the Asian Population. Ann Vasc Surg. 2017. PMID: 28943488. doi:10.1016/j.avsg.2017.09.005

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。