文献速递主动脉疾病内脏/肾动脉与血管畸形

烟囱EVAR术后内脏动脉支架闭塞的血流动力学与解剖预测因素

Hemodynamic and Anatomic Predictors of Renovisceral Stent-Graft Occlusion Following Chimney Endovascular Repair of Juxtarenal Aortic Aneurysms.
PubMed 文献 · J Endovasc Ther · 2017-09-15

该回顾性研究分析了41例近肾腹主动脉瘤烟囱EVAR患者的CT扫描,选取6例(4例至少1支烟囱支架闭塞)进行计算血流动力学分析,发现术后1个月内支架形态改变及局部壁面剪切应力和压力扰动与未来支架闭塞相关,并识别出管腔面积<14 mm²、收缩期压力梯度>25 Pa/mm、收缩期WSS>45 Pa等预测信号。

要点

  • 烟囱支架形态改变及血流动力学扰动与未来闭塞相关。
  • 术后1个月内可识别闭塞预测信号:管腔面积<14 mm²、收缩期压力梯度>25 Pa/mm、收缩期WSS>45 Pa。
  • 早期分析这些参数可能有助于识别并干预高风险烟囱支架。

核心结论

  • 烟囱EVAR术后存在闭塞风险的支架在术后1个月内即表现出解剖和血流动力学特征。

研究设计与样本

  • 回顾性评估2008至2012年41例近肾腹主动脉瘤行烟囱EVAR患者的CT扫描。
  • 选取6例(平均年龄74岁,3例男性;4例至少1支烟囱支架闭塞)进行详细重建和计算血流动力学分析。
  • 对肠系膜上动脉和肾动脉烟囱支架进行横截面积、中心线角度、腔内压力及壁面剪切应力的时空分析。

主要发现

  • 13支支架分支中发生5例闭塞,归因于烟囱支架形态改变及局部WSS和压力扰动。
  • 管腔面积<14 mm²(p=0.04)、收缩期压力梯度>25 Pa/mm(p=0.03)、收缩期WSS>45 Pa(p=0.03)与未来烟囱支架闭塞相关。

关键数值与推荐

  • 管腔面积<14 mm²(p=0.04)与未来烟囱支架闭塞相关。
  • 收缩期压力梯度>25 Pa/mm(p=0.03)与未来烟囱支架闭塞相关。
  • 收缩期WSS>45 Pa(p=0.03)与未来烟囱支架闭塞相关。

临床怎么用

  • 术后早期(1个月内)分析管腔面积、压力梯度和WSS等参数可能有助于识别高风险烟囱支架并进行干预。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To identify anatomic and hemodynamic changes associated with impending visceral chimney stent-graft occlusion after endovascular aneurysm repair (EVAR) with the chimney technique (chEVAR). METHODS: A retrospective evaluation was performed of computed tomography scans from 41 patients who underwent juxtarenal chEVAR from 2008 to 2012 to identify stent-grafts demonstrating conformational changes following initial placement. Six subjects (mean age 74 years; 3 men) were selected for detailed reconstruction and computational hemodynamic analysis; 4 had at least 1 occluded chimney stent-graft. This subset of repairs was systematically analyzed to define the anatomic and hemodynamic impact of these changes and identify signature patterns associated with impending renovisceral stent-graft occlusion. Spatial and temporal analyses of cross-sectional area, centerline angle, intraluminal pressure, and wall shear stress (WSS) were performed within the superior mesenteric and renal artery chimney grafts used for repair. RESULTS: Conformational changes in the chimney stent-grafts and associated perturbations, in both local WSS and pressure, were responsible for the 5 occlusions in the 13 stented branches. Anatomic and hemodynamic signatures leading to occlusion were identified within 1 month postoperatively, with a lumen area <14 mm2 (p=0.04), systolic pressure gradient >25 Pa/mm (p=0.03), and systolic WSS >45 Pa (p=0.03) associated with future chimney stent-graft occlusion. CONCLUSION: Chimney stent-grafts at increased risk for occlusion demonstrated anatomic and hemodynamic signatures within 1 month of juxtarenal chEVAR. Analysis of these parameters in the early postoperative period may be useful for identifying and remediating these high-risk stent-grafts.

来源:J Endovasc Ther,查看原文。版权归原作者所有。

引用

  1. Tricarico R, He Y, Laquian L, et al. Hemodynamic and Anatomic Predictors of Renovisceral Stent-Graft Occlusion Following Chimney Endovascular Repair of Juxtarenal Aortic Aneurysms. J Endovasc Ther. 2017. PMID: 28914135. doi:10.1177/1526602817731096

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。