文献速递主动脉疾病

TEVAR术后胸主动脉几何形态与心脏所致形变的变化

Changes in Geometry and Cardiac Deformation of the Thoracic Aorta after Thoracic Endovascular Aortic Repair.
PubMed 文献 · Ann Vasc Surg · 2017-09-05

本研究通过三维建模量化TEVAR术前后的心脏所致主动脉形变,纳入8例急性或慢性B型夹层及慢性弓部动脉瘤患者。结果显示TEVAR不仅改变支架段几何形态,还使升主动脉在舒张期至收缩期的轴向长度变化增加、平均曲率下降,支架段平均与峰值曲率降低。

要点

  • TEVAR术后升主动脉轴向长度变化增大、平均曲率下降。
  • 支架段主动脉平均曲率和峰值曲率降低,提示支架使血管变直。
  • 支架纵向刚度削弱心脏所致弯曲,由升主动脉形变代偿。

核心结论

  • TEVAR不仅直接改变支架段主动脉几何形态,还引起升主动脉和支架段的动态形变变化。
  • 支架植入使支架段主动脉变直,并因纵向刚度削弱心脏所致弯曲。
  • 升主动脉通过更大的长度和曲率变化代偿支架段的形变减弱。

研究设计与样本

  • 单中心三维建模研究,纳入8例TEVAR患者:急性B型夹层4例、慢性B型夹层3例、慢性弓部动脉瘤1例。
  • 使用单枚Gore C-TAG 5例、多枚Gore C-TAG 3例。
  • 采集TEVAR术前和术后心脏分辨胸部CT,构建收缩期和舒张期胸主动脉及分支血管三维模型。
  • 从以分支血管标志 delineated 的主动脉管腔中心线计算升主动脉、弓部和支架段的轴向长度、平均曲率和峰值曲率。
  • 心脏所致形变从舒张中期至收缩末期计算。

主要发现

  • TEVAR术前,主动脉轴向长度或平均曲率无显著心脏所致变化。
  • TEVAR术后,升主动脉从舒张期至收缩期轴向长度增加2.7 ± 3.1%(P < 0.05),平均曲率下降(0.38 ± 0.05 → 0.36 ± 0.05 cm-1,P < 0.05)。
  • TEVAR前后比较,升主动脉轴向长度变化增加(P < 0.02),弓部和支架段平均曲率下降(P < 0.03),支架段峰值曲率下降(P < 0.05)。

临床怎么用

  • TEVAR术后评估应关注升主动脉和支架段的动态几何变化,而不仅限于支架段静态形态。
  • 支架纵向刚度可能削弱支架段心脏所致弯曲,需注意升主动脉代偿性形变对长期耐久性的潜在影响。

局限性

  • 样本量小(8例),适应证异质(急性/慢性B型夹层及慢性弓部动脉瘤)。
  • 单中心研究,使用单一品牌支架(Gore C-TAG)。
  • 未报告长期临床结局或耐久性数据。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Thoracic endovascular aortic repair (TEVAR) has dramatically expanded treatment options for patients with thoracic aortic pathology. The interaction between endografts and the dynamic anatomy of the thoracic aorta is not well characterized for repetitive physiologic stressors and subsequent issues related to long-term durability. Through three-dimensional (3D) modeling we sought to quantify cardiac-induced aortic deformation before and after TEVAR to assess the impact of endografts on dynamic aortic anatomy. METHODS: Eight patients with acute (n = 4) or chronic (n = 3) type B dissections, or chronic arch aneurysm (n = 1), underwent TEVAR with a single (n = 5) or multiple (n = 3) Gore C-TAG(s). Cardiac-resolved thoracic CT images were acquired pre- and post-TEVAR. 3D models of thoracic aorta and branch vessels were constructed in systole and diastole. Axial length, mean, and peak curvature of the ascending aorta, arch, and stented lumens were computed from the aortic lumen centerline, delineated with branch vessel landmarks. Cardiac-induced deformation was computed from mid-diastole to end-systole. RESULTS: Pre-TEVAR, there were no significant cardiac-induced changes for aortic axial length or mean curvature. Post-TEVAR, the ascending aorta increased in axial length (2.7 ± 3.1%, P < 0.05) and decreased in mean curvature (0.38 ± 0.05 → 0.36 ± 0.05 cm-1, P < 0.05) from diastole to systole. From pre- to post-TEVAR, axial length change increased in the ascending aorta (P < 0.02), mean curvature decreased in the arch and stented aorta (P < 0.03), and peak curvature decreased in the stented aorta (P < 0.05). CONCLUSIONS: TEVAR for a range of indications not only causes direct geometric changes to the stented aorta but also results in dynamic changes to the ascending and stented aorta. In our cohort, endograft placement straightens the stented aorta and mutes cardiac-induced bending due to longitudinal stiffness. This is compensated by greater length and curvature changes from diastole to systole in the ascending aorta, relative to pre-TEVAR.

来源:Ann Vasc Surg,查看原文。版权归原作者所有。

引用

  1. Hirotsu K, Suh GY, Lee JT, et al. Changes in Geometry and Cardiac Deformation of the Thoracic Aorta after Thoracic Endovascular Aortic Repair. Ann Vasc Surg. 2017. PMID: 28887263. doi:10.1016/j.avsg.2017.07.033

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。