影像随访依从性对EVAR术后死亡率的影响:基于人群的队列研究
该研究基于加拿大安大略省行政健康数据库,纳入2004至2014年接受EVAR的4988例患者,评估最低适当影像随访(MAIFU)依从性与全因死亡率的关系。中位随访3.4年,90天死亡率为1.6%;持续符合MAIFU标准与较低死亡风险相关。
要点
- EVAR术后仅58%患者达到MAIFU标准,影像随访依从性不足。
- 持续符合MAIFU与较低死亡风险独立相关。
- 影像随访频率低与血管外科医生随访少相关。
核心结论
- 持续符合最低适当影像随访标准与EVAR术后较低的全因死亡风险相关。
研究设计与样本
- 基于加拿大安大略省行政健康数据库的人群队列研究,纳入2004至2014年接受EVAR的4988例患者。
主要发现
- 中位随访3.4年(IQR 2.0-5.3年),90天死亡率为1.6%。
- 90天后存活者中87%(4251/4902)在90天内至少接受一次腹部CT或超声,但仅58%(2859/4902)达到MAIFU标准。
- 随访期间符合MAIFU的时间比例越大,死亡风险越低。
关键数值与推荐
- MAIFU定义为EVAR术后90天内及之后每15个月进行一次腹部CT或超声检查。
临床怎么用
- 应努力提高EVAR术后影像随访依从性,以改善长期生存。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: Compliance with regular imaging follow-up after endovascular aortic aneurysm repair (EVAR) is inconsistent, and evidence of benefit from scheduled long-term surveillance is limited. This study sought to characterize the association between post-EVAR imaging frequency and long-term survival. METHODS: Using administrative health databases for the province of Ontario, Canada, a cohort of patients was identified who underwent EVAR between 2004 and 2014. Minimum appropriate imaging follow-up (MAIFU) was defined as a CT scan or ultrasound of the abdomen within 90 days of EVAR as well as every 15 months thereafter. Multivariate time to event analyses characterized the association between compliance with MAIFU over time and all-cause mortality. RESULTS: 4988 patients treated by EVAR were identified. Median follow-up was 3.4 years (IQR 2.0-5.3 years) and 90 day mortality was 1.6%. Among those who survived over 90 days, 87% (N = 4251 of 4902) underwent at least one CT scan or ultrasound of the abdomen within 90 days, but only 58% (N = 2859 of 4902) went on to meet MAIFU criteria. Infrequent imaging correlated with lower follow-up by a vascular surgeon, but not with infrequent primary care or specialist consultations. Consistently meeting MAIFU criteria was associated with a lower risk of death when compared with missing the first imaging follow-up within 90 days (HR 0.82, 95% CI 0.69-0.96, p = .014), or when compared with having first imaging follow-up within 90 days but subsequently not meeting MAIFU criteria (HR 0.78, 95% CI 0.68-0.91, p = .001). A larger proportion of the follow-up period meeting MAIFU criteria was associated with a lower risk of death. CONCLUSIONS: These data support efforts to improve compliance with imaging surveillance after EVAR.
引用
- de Mestral C, Croxford R, Eisenberg N, et al. The Impact of Compliance with Imaging Follow-up on Mortality After Endovascular Abdominal Aortic Aneurysm Repair: A Population Based Cohort Study. Eur J Vasc Endovasc Surg. 2017. PMID: 28765015. doi:10.1016/j.ejvs.2017.06.018
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。