三维超声随访小腹主动脉瘤:体积与直径的比较
这项前瞻性队列研究纳入179例小腹主动脉瘤(直径30-55 mm)患者,采用三维超声重复测量直径与体积。随访12个月发现,直径稳定的患者中40%体积仍增长,提示三维超声体积测量可能补充AAA监测。
要点
- 直径稳定的小AAA中40%体积仍增长
- 直径增长者83%伴体积增长
- 三维超声体积或可补充AAA监测
核心结论
- 在小AAA队列中,12个月随访时40%直径稳定的患者体积仍在增长。
- 三维超声未来可能在小AAA监测方案中发挥补充作用。
研究设计与样本
- 前瞻性队列研究,连续纳入179例小肾下腹主动脉瘤(直径30-55 mm)患者。
- 入组时及12个月随访时用双平面技术测最大直径、三维超声测体积。
主要发现
- 125例(70%)随访期间直径不变,其中50例(40%)主动脉体积增长。
- 中位随访367天(364-380天)期间,直径平均增加2.7 mm(±2.6 mm),体积平均增加11.6 mL(±9.9 mL)。
关键数值与推荐
- 直径和体积的显著变化定义为超过各自超声技术已知变异范围(ROV):分别为±3.7 mm和±8.8 mL。
临床怎么用
- 对小AAA患者,除直径外可考虑三维超声体积测量以识别直径稳定但体积增长者。
- 体积增长可能提示需更密切监测或提前干预,但需进一步验证。
局限性
- 事后Kaplan-Meier分析,非预设主要终点。
- 单中心前瞻性队列,随访12个月,结论需更长期验证。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: Rupture risk in abdominal aortic aneurysms (AAAs) is assessed using AAA diameter; yet 10% of ruptures occur in a small aneurysm. This underlines the inadequacy of diameter as a standalone parameter. In this prospective follow-up study, ultrasound determined aneurysm diameter was compared with aneurysm volume determined by three dimensional ultrasound (3D-US) in a group of 179 AAAs. DESIGN: This was a prospective cohort study with repeated diameter and volume measurements by 3D-US. MATERIAL AND METHODS: In total, 179 patients with small infrarenal AAAs (diameter 30-55 mm) were enrolled consecutively. At enrolment and at 12 month follow-up, maximum diameter, using dual plane technique, and three dimensional volume were measured. Based on a previous accuracy study, significant change in diameter and volume were defined as an increase exceeding the known range of variability (ROV) of each US technique; ±3.7 mm and ±8.8 mL, respectively. Post-hoc Kaplan-Meier analysis was performed to estimate time to conversion to treatment after the conclusion of the follow-up period between two groups. RESULTS: In total, 125 patients (70%) had an unchanged diameter during follow-up. In this group, 50 patients (40%) had an increasing aortic volume. Forty-five (83%) of the 54 patients with an increasing aortic diameter showed a corresponding volume increase. During a median follow-up of 367 days (364-380 days), a mean increase in diameter of 2.7 mm (±2.6 mm) and a mean increase in volume of 11.6 mL (±9.9 mL) were recorded. In post-hoc analysis, it was found that more AAAs with a stable diameter and a growing volume than AAAs with a stable diameter and volume were undergoing aortic repair during follow-up, based on the maximum diameter. CONCLUSION: In this cohort of small AAAs, 40% of patients with a stable diameter had an increasing volume at 12 month follow-up. From this perspective, 3D-US could have a future supplemental role in AAA surveillance programmes.
引用
- Ghulam QM, Bredahl KK, Lönn L, et al. Follow-up on Small Abdominal Aortic Aneurysms Using Three Dimensional Ultrasound: Volume Versus Diameter. Eur J Vasc Endovasc Surg. 2017. PMID: 28765014. doi:10.1016/j.ejvs.2017.06.016
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。