烟囱移植物技术治疗主动脉弓疾病的系统评价与荟萃分析
该系统评价与荟萃分析检索截至2016年2月的文献,纳入11项研究共373例患者和387枚烟囱移植物,评估烟囱技术治疗主动脉弓疾病的效果。汇总技术成功率91.3%,围术期Ia型内漏9.4%,30天死亡率7.9%,逆行A型夹层1.8%。结论认为该技术可行有效但并发症风险不容忽视。
要点
- 烟囱技术治疗主动脉弓疾病技术成功率91.3%,早期通畅率97.9%。
- 围术期Ia型内漏发生率9.4%,30天死亡率7.9%,需警惕。
- 逆行A型夹层发生率1.8%,重大卒中2.6%,再干预率10.6%。
核心结论
- 烟囱技术腔内修复主动脉弓疾病技术上可行且有效,但存在主要并发症风险。
研究设计与样本
- 系统评价与荟萃分析,检索PubMed/MEDLINE、Science Direct和Cochrane Library截至2016年2月的文献。
- 纳入11篇出版物,共373例患者和387枚烟囱移植物。
主要发现
- 总体技术成功估计比例为91.3%(95%CI 87.4%-94.0%)。
- 373例患者中26例(7%)围术期发生Ia型内漏,总体早期Ia型内漏估计比例为9.4%(95%CI 6.5%-13.4%)。
- 10项研究提供数据,351例中2例发生逆行A型夹层,总体估计比例为1.8%(95%CI 0.8%-4.0%)。
- 汇总30天死亡率为7.9%(95%CI 4.6%-13.2%),再干预为10.6%(95%CI 5%-21%),重大卒中为2.6%(95%CI 1.3%-5.0%)。
- 早期通畅率为97.9%(95%CI 95.8%-99%),晚期通畅率为92.9%(95%CI 87.3%-96%)。
临床怎么用
- 烟囱技术可作为主动脉弓疾病腔内治疗的替代选择,但需权衡内漏、卒中和逆行夹层等风险。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: The aim of this study was to provide a review of the literature on the use of chimney graft (CG) technique in treating arterial diseases of the aortic arch and to extrapolate conclusions by summarizing the reported outcomes in a meta-analysis. METHODS: An extensive electronic search was made using PubMed/MEDLINE, Science Direct Databases, and the Cochrane Library. Included in this meta-analysis were all papers published up to February 2016 on endovascular chimney technique in the arch vessels with or without adjunct extra-anatomic debranching, in any language, providing data about at least one of the essential outcomes: early and late type I endoleak, 30-day mortality rate, development of perioperative stroke, patency, and retrograde aortic dissection. RESULTS: Of the 478 reports yielded by the electronic search, a total of 11 publications (on 373 patients and 387 CGs) fulfilled the inclusion criteria and were included in this study. The overall estimated proportion of technical success was 91.3% (95% confidence interval [CI], 87.4%-94.0%). Of the 373 patients, 26 (7%) experienced a type Ia endoleak in the perioperative period. The overall estimated proportion of early type Ia endoleak was 9.4% (95% CI, 6.5%-13.4%). Among the 10 studies that provided data, a retrograde type A dissection was observed in 2 of 351 patients, resulting in an overall estimated proportion of 1.8% (95% CI, 0.8%-4.0%). The pooled 30-day mortality rate was 7.9% (95% CI, 4.6%-13.2%). The pooled estimation for reintervention was 10.6% (95% CI, 5%-21%); for major stroke, 2.6% (95% CI, 1.3%-5.0%); for early patency, 97.9% (95% CI, 95.8%-99%); and for late patency, 92.9% (95% CI, 87.3%-96%). CONCLUSIONS: Treatment of aortic diseases involving the aortic arch poses a great challenge. The CG technique has been applied as an alternative treatment option. This meta-analysis shows that endovascular repair of aortic arch disease using a CG technique in the aortic arch vessels is technically feasible and effective but not without major risk of complications.
引用
- Ahmad W, Mylonas S, Majd P, et al. A current systematic evaluation and meta-analysis of chimney graft technology in aortic arch diseases. J Vasc Surg. 2017. PMID: 28847663. doi:10.1016/j.jvs.2017.06.100
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。