VNUS Closure射频消融治疗静脉曲张主干反流15年结果
该研究对1999–2001年接受VNUS Closure射频消融的189例患者进行15年后的前瞻性审计,58例(91条腿,101条主干静脉)返回随访。平均15.4年时,88%患者原治疗静脉无临床复发,但51.6%的腿出现新发反流,显示疾病进展。
要点
- VNUS Closure射频消融15年后88%患者原治疗主干静脉无临床复发。
- 51.6%的腿出现新发反流,提示原正常静脉疾病进展。
- 100%患者对手术满意,98%愿意推荐该手术。
核心结论
- VNUS Closure射频消融治疗主干静脉反流15年后经双功能超声证实具有极好的长期技术成功率。
研究设计与样本
- 最终58例(91条腿,101条主干静脉)返回随访,应答率31.5%。
主要发现
- 平均术后15.4年,51例(56%)报告无静脉曲张,58例(100%)对手术满意,57例(98%)愿意推荐手术。
- 双功能超声显示88%的患者原治疗静脉达到成功且无临床复发。
- 91条腿中47条(51.6%)发现新发反流,显示原正常静脉疾病进展。
关键数值与推荐
- 双功能超声 outcome 分级:1级完全成功(完全萎缩);2级部分成功(>1段通畅但未引起复发性静脉曲张);3级部分失败(≥1段通畅且引起复发性静脉曲张);4级完全失败。
- 2条主干静脉因部分或完全失败在外院治疗后被排除。
临床怎么用
- VNUS Closure射频消融可作为治疗主干静脉反流的有效选择,长期技术成功率高。
- 术后15年仍需关注新发反流和疾病进展,建议长期随访。
局限性
- 应答率仅31.5%,多数患者因搬迁或死亡失访,可能存在选择偏倚。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: Endovenous thermal ablation (EVTA) of varicose veins was introduced in the late 1990s with radiofrequency ablation (RFA) using the VNUS Closure device. The results of the original VNUS Closure device for the abolition of truncal venous reflux at 15 years are reported. METHODS: A prospective audit of a group of patients treated with VNUS Closure 15 years previously was carried out, using clinical assessment and duplex ultrasound. A total of 189 patients were treated with VNUS Closure between March 1999 and December 2001 and were invited for clinical assessment (subjective and objective) and duplex ultrasonography (DUS) to assess treatment outcome and de novo disease progression. DUS outcome of the treated vein was graded: 1, complete success (complete atrophy); 2, partial success (> 1 patent section; none giving rise to recurrent varicose veins); 3, partial failure (≥ 1 patent sections giving rise to recurrent varicose veins); 4, complete failure. RESULTS: Fifty-eight patients (91 legs, 101 truncal veins) returned for follow-up DUS, giving a 31.5% response rate (many patients had moved or had died in the 15 years). Two truncal veins had been excluded following treatment elsewhere presumably for partial or complete failure. At a mean of 15.4 years post-procedure, 51 (56%) reported no varicose veins, 58 (100%) that they were pleased that they had the procedure and 57 (98%) that they would recommend the procedure. DUS showed 88% of patients achieved success with no clinical recurrence in the originally treated veins. De novo reflux was identified in 47 of 91 legs (51.6%), showing disease progression in veins that were originally competent. CONCLUSIONS: RFA with VNUS Closure achieved excellent long-term technical success in treating venous reflux in truncal veins 15 years post-procedure, demonstrated by DUS. This bodes well for the increased use of EVTA in treating truncal vein reflux.
引用
- Whiteley MS, Shiangoli I, Dos Santos SJ, et al. Fifteen Year Results of Radiofrequency Ablation, Using VNUS Closure, for the Abolition of Truncal Venous Reflux in Patients with Varicose Veins. Eur J Vasc Endovasc Surg. 2017. PMID: 28697961. doi:10.1016/j.ejvs.2017.06.001
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。