文献速递颈动脉与弓上血管

声辐射力脉冲超声成像用于颈动脉斑块成分表征的组织学验证

Performance of acoustic radiation force impulse ultrasound imaging for carotid plaque characterization with histologic validation.
PubMed 文献 · J Vasc Surg · 2017-07-13

本研究在25例接受颈动脉内膜切除术的患者术前采集颈动脉声辐射力脉冲(ARFI)弹性成像图像,并与组织学切片配准对照,由3名对组织学不知情的放射科医生评估斑块成分。结果显示ARFI峰值位移在坏死核心与斑块内出血区域比胶原或钙化区域大2至4倍,识别软斑块成分的AUC中位数为0.887,识别硬斑块成分为0.859,部分读片者的纤维帽厚度测量与组织学相关。提示ARFI可区分软、硬动脉粥样硬化斑块成分并描绘纤维帽厚度。

要点

  • ARFI峰值位移在坏死核心和斑块内出血区比胶原或钙化区大2至4倍。
  • 识别软斑块成分(坏死核心/斑块内出血)的AUC中位数为0.887。
  • 识别硬斑块成分(胶原/钙化)的AUC中位数为0.859。

核心结论

  • ARFI成像能够区分软性与硬性动脉粥样硬化斑块成分,并可描绘纤维帽厚度。

研究设计与样本

  • 前瞻性术前成像与组织学验证研究,纳入25例接受临床指征颈动脉内膜切除术的患者。
  • 术前采集颈动脉ARFI图像,手术标本切片与超声成像平面匹配后进行组织学处理。
  • 3名对组织学不知情的放射科医生评估ARFI诱导峰值位移参数图,以组织学为标准。
  • 采用受试者工作特征曲线分析、线性回归、Spearman相关(ρ)和Bland-Altman分析评价读片表现。

主要发现

  • ARFI峰值位移在坏死核心和斑块内出血区域比胶原或钙化区域大2至4倍。
  • 读片者识别软斑块特征(坏死核心/斑块内出血)的AUC中位数为0.887(范围0.867-0.924)。
  • 读片者识别硬斑块特征(胶原/钙化)的AUC中位数为0.859(范围0.771-0.929)。
  • 3名读片者中有2名的纤维帽厚度测量与组织学相关(读片者1:R2=0.64,ρ=0.81;读片者2:R2=0.89,ρ=0.75)。

临床怎么用

  • ARFI可作为无创超声弹性成像手段,用于术前评估颈动脉斑块成分及纤维帽厚度。
  • 斑块软硬成分的区分有助于识别易损斑块,为颈动脉狭窄患者的风险分层提供补充信息。

局限性

  • 样本量仅25例,且均为接受颈动脉内膜切除术的患者,存在选择偏倚。
  • 纤维帽厚度测量仅在3名读片者中的2名与组织学相关,重复性有限。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: Stroke is commonly caused by thromboembolic events originating from ruptured carotid plaque with vulnerable composition. This study assessed the performance of acoustic radiation force impulse (ARFI) imaging, a noninvasive ultrasound elasticity imaging method, for delineating the composition of human carotid plaque in vivo with histologic validation. METHODS: Carotid ARFI images were captured before surgery in 25 patients undergoing clinically indicated carotid endarterectomy. The surgical specimens were histologically processed with sectioning matched to the ultrasound imaging plane. Three radiologists, blinded to histology, evaluated parametric images of ARFI-induced peak displacement to identify plaque features such as necrotic core (NC), intraplaque hemorrhage (IPH), collagen (COL), calcium (CAL), and fibrous cap (FC) thickness. Reader performance was measured against the histologic standard using receiver operating characteristic curve analysis, linear regression, Spearman correlation (ρ), and Bland-Altman analysis. RESULTS: ARFI peak displacement was two-to-four-times larger in regions of NC and IPH relative to regions of COL or CAL. Readers detected soft plaque features (NC/IPH) with a median area under the curve of 0.887 (range, 0.867-0.924) and stiff plaque features (COL/CAL) with median area under the curve of 0.859 (range, 0.771-0.929). FC thickness measurements of two of the three readers correlated with histology (reader 1: R2 = 0.64, ρ = 0.81; reader 2: R2 = 0.89, ρ = 0.75). CONCLUSIONS: This study suggests that ARFI is capable of distinguishing soft from stiff atherosclerotic plaque components and delineating FC thickness.

来源:J Vasc Surg,查看原文。版权归原作者所有。

引用

  1. Czernuszewicz TJ, Homeister JW, Caughey MC, et al. Performance of acoustic radiation force impulse ultrasound imaging for carotid plaque characterization with histologic validation. J Vasc Surg. 2017. PMID: 28711401. doi:10.1016/j.jvs.2017.04.043

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。