文献速递主动脉疾病

Ovation支架移植物真实世界经验:150例患者治疗教训

Real-Life Experience with Ovation Stent Graft: Lesson Learned from the First One Hundred Fifty Treated Patients.
PubMed 文献 · Ann Vasc Surg · 2017-07-06

术前不利解剖因素与再干预无显著相关。

要点

  • 30天I型内漏发生率1.3%,1例经近端主动脉袖套植入成功处理
  • 主动脉颈≤10 mm等不利解剖因素与再干预无显著相关

核心结论

  • 在未经筛选的AAA患者中,使用Ovation支架行EVAR安全可行,即刻和中期结果令人满意。

主要发现

  • 1例支架腿闭塞经药物治疗;平均随访20.4±8.8个月(范围1-60)共6例再干预,包括2例II型内漏栓塞和4例髂/股血管闭塞性疾病。

关键数值与推荐

  • 主动脉分叉平均直径≤18 mm者31例(19.9%),分叉面积≤20 mm²者35例(22.4%)。
  • 再干预自由度的Log-rank检验P值:颈长≤10 mm为0.653,非圆柱形颈为0.309,分叉平均直径≤18 mm为0.520,分叉面积≤20 mm²为0.604,髂外动脉直径≤5 mm为0.421。

临床怎么用

  • Ovation支架可考虑用于包括短颈、非圆柱形颈等不利解剖的未经筛选AAA人群,但仍需规范随访监测内漏和再干预。

局限性

  • 回顾性设计、样本量有限、随访时间较短,且为两家中心经验,结果外推需谨慎。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The objective of the study was to report immediate and midterm results of an unselected population of patients treated for abdominal aortic aneurysms (AAAs) by endovascular aneurysm repair (EVAR) using the Ovation stent graft. METHODS: A double-center retrospective study was conducted on a prospectively collected database between 2012 and 2015. One hundred fifty-six elective patients were included. The outcome measures considered for analysis were primary technical success, 30-day and midterm reinterventions, and all-cause and AAA-related mortality rates. The presence of an aortic neck ≤10 mm, and of a noncylindrical aortic neck, as well as a narrowed aortic bifurcation was defined as an aortic bifurcation average diameter (ABaverage) ≤ 18 mm or an ABarea ≤ 20 mm2, and an external iliac artery diameter ≤5 mm was considered as independent factors potentially influencing the outcome. RESULTS: Male patients totaled 128 (82.1%), and mean age was 74.83 ± 6.76 years (range: 56-91). Mean aortic diameter was 57.15 ± 8.77 mm, mean diameter at inferior renal artery level + 13 was 24.44 ± 3.31 mm, and mean aortic neck length was 18.77 ± 8.45 mm. Fifty-four patients (34.6%) had an aortic neck ≤10 mm, and cylindrical aortic neck shape was present in 34 patients (21.8%). Regarding the aortic bifurcation (AB), 31 patients (19.9%) presented ABaverage ≤ 18 mm, and 35 (22.4%) an ABarea ≤ 20 mm2. Technical success was achieved in all cases. At 30-day follow-up, 2 type I endoleaks (1.3%) were detected. One patient was successfully treated endovascularly by proximal aortic cuff implantation, while the other patient refused further treatment. Three-month unscheduled computed tomographic angiography shows endoleak resolution and complete aneurysm seal. One patient suffered from a limb graft occlusion, managed by medical treatment. At a mean follow-up time of 20.4 ± 8.8 (1-60) months, 6 reinterventions were reported, including 2 embolizations for type II endoleak and 4 for iliac and femoral vessel occlusive disease. Log-rank test on preoperative anatomical features showed no significant differences in terms of freedom from reinterventions, and P values were 0.653 for aortic neck length ≤10 mm, 0.309 for noncylindrical aortic neck length shape, 0.520 for ABaverage ≤ 18 mm, 0.604 for ABarea ≤ 20 mm2, and 0.421 for external iliac artery diameter ≤5 mm. CONCLUSIONS: Our initial experience suggests that in an unselected patient population undergoing AAA repair, EVAR by Ovation stent graft can be performed safely with satisfactory immediate and midterm outcomes.

来源:Ann Vasc Surg,查看原文。版权归原作者所有。

引用

  1. Sirignano P, Mansour W, Pranteda C, et al. Real-Life Experience with Ovation Stent Graft: Lesson Learned from the First One Hundred Fifty Treated Patients. Ann Vasc Surg. 2017. PMID: 28689943. doi:10.1016/j.avsg.2017.06.140

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。