Conformable支架治疗急性复杂与不复杂B型主动脉夹层的早期 outcomes
本研究评估Conformable胸主动脉内移植物(CTAG)治疗急性复杂与不复杂B型主动脉夹层(TBAD)的安全性、有效性和结局。所有患者存活,无内漏、逆行夹层、远端新破口、卒中或截瘫;复杂与不复杂TBAD的最小真腔面积均显著增加,但不复杂夹层的最大假腔面积显著减小,复杂夹层无变化。
要点
- CTAG装置治疗急性TBAD早期无主要并发症,临床有效且顺应性良好。
- 复杂与不复杂急性TBAD的最小真腔面积均显著增加。
- 不复杂夹层最大假腔面积显著减小,复杂夹层无显著变化。
核心结论
- CTAG装置治疗急性复杂与不复杂TBAD早期临床有效且顺应性良好,无主要并发症风险。
主要发现
- 所有患者随访期间存活,术后未观察到内漏、逆行主动脉夹层、远端新破口、卒中或截瘫。
- 2例(3.8%)出现轻微伤口血肿,无需进一步治疗。
- 7例(13.5%)观察到鸟嘴构型,其中5例接受了烟囱技术。
- 复杂与不复杂急性TBAD的最小真腔面积均显著增加(P < .001和P = .047);不复杂夹层最大假腔面积显著减小(P = .006),复杂夹层无变化(P = .32)。
临床怎么用
- 对于急性复杂与不复杂TBAD,CTAG装置可作为早期治疗选择,需关注鸟嘴构型及烟囱技术使用。
局限性
- 样本量较小且随访时间较短,需更大样本和更长随访评估远期结局。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: The objective of this study was to evaluate the safety, efficacy, and outcomes of the conformable thoracic endograft (Conformable TAG Thoracic Endoprosthesis [CTAG]; W. L. Gore & Associates, Flagstaff, Ariz) for acute complicated and uncomplicated type B aortic dissection (TBAD). METHODS: Between February and October 2016, 52 consecutive patients with acute complicated or uncomplicated TBAD were treated with a CTAG device. We assessed safety, complications, and device conformability using intraoperative angiography and computed tomography angiography. The mean follow-up period was 8.2 ± 3.5 months (range, 4-12 months). RESULTS: All patients survived through the follow-up period. No endoleaks, retrograde aortic dissection, distal new entry tear, stroke, or paraplegia was observed postoperatively. Two patients (3.8%) experienced minor wound hematomas without further treatment. Eleven patients (21.2%) underwent a chimney technique to rebuild supra-arch vessels. A bird-beak configuration was observed in seven (13.5%) patients, five of whom underwent a chimney technique. Analysis of aortic remodeling showed that the minimal true lumen area significantly increased in both complicated and uncomplicated acute TBAD (P < .001 and P = .047, respectively). Likewise, the maximal false lumen area significantly decreased in uncomplicated dissection (P = .006), but no change in maximal false lumen area was detected in complicated dissection (P = .32). CONCLUSIONS: Early outcomes indicate that the CTAG device provides reliable clinical effectiveness and excellent conformability in treating acute complicated and uncomplicated TBAD without risk of major complications. Studies with larger sample sizes and longer follow-up periods are required to evaluate longer term outcomes.
引用
- Zhu T, Si Y, Fang Y, et al. Early outcomes of the conformable stent graft for acute complicated and uncomplicated type B aortic dissection. J Vasc Surg. 2017. PMID: 28697941. doi:10.1016/j.jvs.2017.04.050
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。