文献速递主动脉疾病

限制性裸支架预防B型主动脉夹层TEVAR远端SINE

Restrictive bare stent prevents distal stent graft-induced new entry in endovascular repair of type B aortic dissection.
PubMed 文献 · J Vasc Surg · 2017-07-13

本研究探讨B型主动脉夹层TEVAR术后远端支架诱导新发破口(SINE)的机制及限制性裸支架(RBS)的预防作用。2013至2014年连续68例患者中,23例接受标准TEVAR,45例接受TEVAR联合RBS;TEVAR组发生4例远端SINE,RBS组0例,且RBS组远端过度尺寸和扩张不匹配比更低,假腔缩小更显著。

要点

  • 远端过度尺寸和扩张不匹配比可能与远端SINE发生相关。
  • TEVAR联合RBS可降低远端SINE发生率(0/45 vs 4/23)。
  • RBS植入可能改善主动脉重塑,假腔在RBS远端边缘显著缩小。

核心结论

  • 远端过度尺寸和扩张不匹配比可能是远端SINE的原因。
  • RBS技术降低了远端SINE发生率,并可能改善主动脉重塑。

研究设计与样本

  • 回顾性连续病例研究,2013年1月至2014年12月共68例B型主动脉夹层患者接受血管内修复。
  • 23例接受单纯TEVAR,45例接受TEVAR联合RBS技术。

主要发现

  • TEVAR组发生4例远端SINE,TEVAR+RBS组0例(4/23 [17.4%] vs 0/45 [0%];P = .011)。
  • SINE患者远端过度尺寸显著更高(69.7% ± 35.5% vs 31.2% ± 24.5%;P = .005)。
  • SINE患者扩张不匹配比显著更高(132.2% ± 16.9% vs 106.5% ± 11.6%;P < .05)。
  • TEVAR+RBS组远端过度尺寸更低(59.8% ± 24.7% vs 16.7% ± 7.6%;P < .05)。
  • TEVAR+RBS组扩张不匹配比更低(113.8% ± 14.6% vs 103.8% ± 11.7%;P = .012)。

关键数值与推荐

  • RBS技术用于远端过度尺寸(胸主动脉支架直径与支架远端预期边缘水平降主动脉真腔直径之差)>20%的患者。

临床怎么用

  • 对于远端过度尺寸>20%的B型主动脉夹层TEVAR患者,可考虑联合RBS技术以预防远端SINE。
  • 术中应关注远端过度尺寸和扩张不匹配比,避免过度扩张。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: Distal stent graft-induced new entry (SINE) can occur after thoracic endovascular aortic repair (TEVAR) of type B aortic dissection. This study investigated the mechanism of distal SINE and its prevention using a restrictive bare stent (RBS) technique. METHODS: From January 2013 to December 2014, 68 consecutive type B aortic dissection patients received endovascular repair at our center. The RBS technique was used with distal oversizing (between the diameter of the thoracic stent graft and the descending aorta true lumen diameter at the level of the intended distal edge of the thoracic stent graft) >20%. RESULTS: Twenty-three patients received TEVAR with a single thoracic stent graft (TEVAR group, n = 23); the rest received TEVAR combined with the RBS technique (TEVAR + RBS group, n = 45). Four distal SINEs occurred in the TEVAR group. Distal oversizing (69.7% ± 35.5% vs 31.2% ± 24.5%; P = .005) and expansion mismatch ratio (132.2% ± 16.9% vs 106.5% ± 11.6%; P < .05) were significantly higher in the SINE patients. Compared with standard TEVAR, TEVAR + RBS was associated with significantly lower distal oversizing (TEVAR vs TEVAR + RBS group, 59.8% ± 24.7% vs 16.7% ± 7.6%; P < .05), lower expansion mismatch ratio (113.8% ± 14.6% vs 103.8% ± 11.7%; P = .012), and lower distal SINE rate (4/23 [17.4%] vs 0/45 [0%]; P = .011). Compared with the TEVAR group, the false lumen was reduced significantly at the level of the RBS distal edge (P = .029). CONCLUSIONS: Excessive distal oversizing and distal expansion mismatch ratio may contribute to the occurrence of distal SINE. The RBS technique reduced the incidence of distal SINE. Based on our midterm and long-term observations, implantation of an RBS may improve aortic remodeling.

来源:J Vasc Surg,查看原文。版权归原作者所有。

引用

  1. Zhao Y, Yin H, Chen Y, et al. Restrictive bare stent prevents distal stent graft-induced new entry in endovascular repair of type B aortic dissection. J Vasc Surg. 2017. PMID: 28711399. doi:10.1016/j.jvs.2017.04.066

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。