文献速递主动脉疾病

EVAS与EVAR炎症反应倾向性评分匹配分析

A Propensity Score-Matched Analysis of Inflammatory Response With Endovascular Aneurysm Sealing vs Endovascular Aneurysm Repair.
PubMed 文献 · J Endovasc Ther · 2017-07-24

单中心回顾性研究纳入41例EVAS和63例EVAR腹主动脉瘤患者,经倾向性评分匹配各39例比较。EVAS组植入后综合征发生率、体温、白细胞计数及hs-CRP均呈比例性降低,但植入后综合征发生率差异未达显著(p=0.07)。聚酯支架移植物围术期炎症反应最强。

要点

  • EVAS较EVAR系统性炎症反应更轻,白细胞计数和hs-CRP显著更低。
  • 聚酯支架移植物围术期炎症反应最强,选择移植物材料影响术后结局。
  • EVAS组严重不良事件和內漏数值上更少,但差异未达统计学显著。

核心结论

  • EVAS与EVAR相比系统性炎症反应减弱。
  • 聚酯支架移植物引起最强的围术期炎症反应。

研究设计与样本

  • 单中心2013年12月至2015年5月回顾性队列,EVAS组41例(平均年龄72±9岁,38例男性),EVAR组63例(平均年龄74±10岁,55例男性)。
  • 采用倾向性评分匹配控制治疗选择偏倚,匹配后每组39例进行比较。

主要发现

  • 匹配后EVAS组植入后综合征发生率p=0.07,平均体温p=0.05,平均白细胞计数p=0.003,平均hs-CRP p<0.001,均呈比例性低于EVAR组。
  • 30天内严重不良事件EVAS组0% vs EVAR组12.8%(p=0.05),內漏0% vs 10.3%(p=0.13),组间差异均未达统计学显著。

关键数值与推荐

  • 植入后综合征定义为体温>38°C且白细胞计数>12,000/µL。
  • 主要结局为30天内植入后综合征、炎症反应标志物(血小板和高敏C反应蛋白)及临床并发症。

临床怎么用

  • EVAS可能减轻腹主动脉瘤腔内修复术后炎症反应,选择支架移植物材料时需考虑聚酯材料的炎症效应。

局限性

  • 单中心回顾性研究,样本量有限,部分结局差异未达统计学显著。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To evaluate the risk of postimplantation syndrome associated with endovascular aneurysm sealing (EVAS) and endovascular aneurysm repair (EVAR) in patients treated for abdominal aortic aneurysm (AAA). METHODS: From December 2013 to May 2015, 41 AAA patients treated with EVAS (mean age 72±9 years; 38 men) and 63 with EVAR (mean age 74±10 years; 55 men) at a single center were retrospectively reviewed. To control for treatment selection bias, propensity score matching was used to compare outcomes by treatment mode. Main outcomes were postimplantation syndrome (defined as temperature >38°C and leukocyte count >12,000/µL), inflammatory response markers [platelets and high-sensitivity C-reactive protein (hs-CRP)], and clinical complications through 30 days. RESULTS: In 39 matched patients per group, the incidences of postimplantation syndrome (p=0.07), mean body temperature (p=0.05), mean leukocyte count (p=0.003), and mean hs-CRP (p<0.001) were proportionally lower with EVAS vs EVAR. Serious adverse events (0% vs 12.8%, p=0.05) and endoleaks (0% vs 10.3%, p=0.13) through 30 days were less frequent with EVAS, but the group differences were not significantly different. The choice of endovascular graft material influenced postoperative and 30-day clinical outcomes, with greater overall risk observed with polyester stent-grafts. CONCLUSION: Endovascular aneurysm sealing is associated with a blunted systematic inflammatory response compared with EVAR. Polyester stent-grafts induce the greatest periprocedural inflammatory response.

来源:J Endovasc Ther,查看原文。版权归原作者所有。

引用

  1. Berg P, Stroetges RA, Miller LE, et al. A Propensity Score-Matched Analysis of Inflammatory Response With Endovascular Aneurysm Sealing vs Endovascular Aneurysm Repair. J Endovasc Ther. 2017. PMID: 28737060. doi:10.1177/1526602817722019

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。