烟囱移植物腔内修复术的中期结果与沟槽面积演变
中位随访26个月,2年估计生存率78.1%,沟槽面积随时间小幅但显著减小。结论认为该标准化方案适用于不适合开放或开窗EVAR的高危复杂动脉瘤患者,但分支血管丢失和再干预率提示应严格选择真正禁忌开放或开窗修复的患者。
要点
- 烟囱移植物EVAR在高危复杂动脉瘤中主要技术成功率87.9%,早期死亡率6.1%。
- 2年估计生存率78.1%,次要临床成功率80.5%,无动脉瘤增长率84.4%。
- 沟槽面积在近端标记处及远端10 mm处随时间小幅但显著减小。
核心结论
- 标准化烟囱移植物EVAR是适合开放和开窗EVAR禁忌的高危复杂动脉瘤患者的可接受选择,但应严格限制用于真正禁忌开放或开窗修复者。
研究设计与样本
- 采用标准化手术流程:左肱或腋动脉切开入路放置烟囱移植物,双侧股动脉切开入路放置主动脉主体装置。
- 结局按血管外科学会报告标准记录,并评估沟槽面积随时间的变化。
主要发现
- 计划置入54枚烟囱移植物,实际置入54枚;主要技术成功率87.9%,30天次要临床成功率84.8%。
- 早期死亡率6.1%(n=2),早期IA型内漏率6.1%(n=2),烟囱移植物闭塞率6.1%(n=2)。
- 中位随访26个月(四分位距14.8-37.3个月),2年估计生存率78.1%(标准误±7.4%)。
- 晚期并发症包括IA型内漏(n=1)、烟囱移植物闭塞(n=2)、II型内漏伴动脉瘤增长(n=4)、远端支架移植物分支扭结闭塞(n=1)。
- 2年估计次要临床成功率80.5%(±7.2%),无动脉瘤增长率84.4%(±7.2%);沟槽面积在近端标记处及远端10 mm处随时间小幅但显著减小。
临床怎么用
- 对于不适合开放手术且被排除在开窗EVAR之外的高危大复杂动脉瘤患者,可考虑标准化烟囱移植物EVAR。
- 术后需监测内漏、烟囱移植物闭塞及动脉瘤增长,必要时行再干预(栓塞、延伸、开放结扎等)。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: The objective of this study was to describe our experience with endovascular aneurysm repair (EVAR) with the use of chimney grafts for branch vessel preservation. METHODS: Patients treated with a chimney graft procedure between October 2009 and May 2015 were included for analysis. Patients who were not considered eligible for open surgical repair or for conventional, branched, or fenestrated endovascular repair were selected. A standardized operating procedure with left brachial or axillary artery cutdown access for the chimney grafts and bilateral femoral artery cutdown access for the aortic main device was used. Outcomes were noted according to the Society for Vascular Surgery reporting standards. In addition, evolution of gutter area over time was determined. Estimated rates of survival, freedom from aneurysm growth, and clinical success at 24 months of follow-up were calculated. RESULTS: Thirty-three patients (mean age, 77.6 ± 6.8 years; 87.9% male) with a mean preoperative maximum aneurysm diameter of 71.7 ± 13.5 mm were included. A total of 54 of an intended 54 chimney grafts were deployed. Primary technical success and 30-day secondary clinical success rates were 87.9% and 84.8%, respectively. The early mortality rate was 6.1% (n = 2). The early type IA endoleak rate was 6.1% (n = 2), and the chimney graft occlusion rate was 6.1% (n = 2). Median follow-up duration was 26 months (interquartile range, 14.8-37.3 months). The estimated 2-year actuarial survival rate was 78.1% (standard error, ±7.4%). Late complications included type IA endoleak (n = 1), chimney graft occlusion (n = 2), type II endoleak with aneurysm growth (n = 4), and distal stent graft limb kinking and occlusion (n = 1). Late reinterventions included coil or glue embolization (n = 3), distal limb extension (n = 2), open endoleak ligation (n = 2), Palmaz stent placement (n = 1), repeated EVAR (n = 1), and femorofemoral bypass graft (n = 1). At 2 years, the estimated secondary clinical success and freedom from aneurysm growth rates were 80.5% (±7.2%) and 84.4% (±7.2%). Gutter size showed a small but significant decrease over time at the level of the proximal markers and at 10 mm distal from the markers. CONCLUSIONS: Midterm results show that a standardized procedure for EVAR using chimney grafts for branch vessel preservation is an acceptable option for high-risk patients with large, complex aneurysms who are unfit for open repair and who have been excluded from fenestrated EVAR. Gutter size decreases over time, but the rate of branch vessel loss and reinterventions demonstrate that this approach should remain reserved for those who are at truly prohibitive risk for open or fenestrated stent graft repair.
引用
- de Beaufort HWL, Cellitti E, de Ruiter QMB, et al. Midterm outcomes and evolution of gutter area after endovascular aneurysm repair with the chimney graft procedure. J Vasc Surg. 2017. PMID: 28668275. doi:10.1016/j.jvs.2017.04.067
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。