高危患者主动脉弓上分支烟囱与潜望镜支架的中期结果
PURPOSE: Report mid-term outcomes of thoracic endovascular aneurysm repair (TEVAR) with chimney and periscope grafts (CPG) in supra-aortic branches (SAB).…
要点
- CPG技术在高危主动脉瘤患者中安全可行,中短期结果良好
- 围术期死亡12%,2年生存率75%,无分支闭塞率96%
- 需更长随访后方可考虑用于中危患者
核心结论
- 烟囱与潜望镜支架技术治疗累及主动脉弓上分支的主动脉瘤安全可行,即使急诊使用现货器械亦如此。
- 该高危人群中期随访结果良好,但需更长随访后才能用于中危患者。
研究设计与样本
- 所有患者均被认为传统手术高危,其中37%非择期手术。
主要发现
- 近端锚定区位于0区49%、1区17%、2区34%;技术成功率95%。
- 围术期并发症和神经系统事件6例(14.6%),死亡5例(12%)。
- 中位随访21.2个月(均值22,标准差18,范围0-65)时,I/III型内漏3例(7%),再干预6例(15%)。
临床怎么用
- 对于传统手术高危、累及主动脉弓上分支的主动脉瘤患者,可考虑采用烟囱/潜望镜支架技术,包括急诊使用现货器械。
- 术后需密切随访内漏、分支闭塞及动脉瘤囊变化,中期结果良好但需更长证据支持。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: Report mid-term outcomes of thoracic endovascular aneurysm repair (TEVAR) with chimney and periscope grafts (CPG) in supra-aortic branches (SAB). METHODS: Retrospective analysis, from October 2009 to May 2014, of patients with aneurysms requiring TEVAR with zone 0/1/2 proximal landing in association with at least one CPG in the SAB. All patients were considered at high risk for conventional surgery. Peri-operative mortality and morbidity, retrograde type A dissection, maximum aortic transverse diameter (TD) and its post-operative evolution, endoleak, survival, freedom from cardiovascular re-interventions, and CPG freedom from occlusion during the follow-up were analysed. RESULTS: Forty-one patients (28.05% EuroScore II) with thoraco-abdominal aortic aneurysm (17%), arch aneurysm (39%), descending aneurysm (34%), and aneurysm extending from the arch to the visceral aorta (10%) were included. Fifteen (37%) patients were treated non-electively. Fifty-nine SABs were treated with the CPG technique: one, two, three, and four CPG were employed in 71%, 19%, 5%, and 5% of patients, respectively. The proximal landing was in zone 0 in 49% of patients, zone 1 in 17%, and zone 2 in 34%. Technical success was 95%. Peri-operative complications and neurological events were registered in six (14.6%) patients and there were 5 deaths (12%). At a median follow-up of 21.2 (mean 22, SD 18; range 0-65) months, type I/III endoleaks were registered in three (7%) cases and re-intervention in six (15%) patients. A significant aneurysm sac shrinkage (p<.001) was reported at mean follow-up and no significant aneurysm sac increase (>5 mm). The estimated 2 year survival, freedom from re-intervention, freedom from endoleak, and freedom from branch occlusion were 75%, 77%, 86%, and 96%, respectively. CONCLUSION: The chimney and periscope grafts technique was shown to be safe in aortic aneurysm disease involving the supra aortic branches, even in an emergency setting using off the shelf devices. Mid-term follow-up results in this high risk population are good, but longer follow-up is mandatory before this technique is used in intermediate-risk patients.
引用
- Pecoraro F, Lachat M, Cayne NS, et al. Mid-term Results of Chimney and Periscope Grafts in Supra-aortic Branches in High Risk Patients. Eur J Vasc Endovasc Surg. 2017. PMID: 28754428. doi:10.1016/j.ejvs.2017.06.014
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。