文献速递慢性静脉疾病内脏/肾动脉与血管畸形

脊柱融合术后医源性髂腔静脉瘘致高输出量心衰的血管内修复

Endovascular Repair of Iatrogenic Iliocaval Fistula Causing High-Output Cardiac Failure after Spine Fusion.
PubMed 文献 · Ann Vasc Surg · 2017-06-21

一例35岁女性脊柱术后3年出现进行性呼吸困难和右心衰竭,查体闻及下腹部连续性杂音,超声示右心室增大、功能性三尖瓣反流及中度肺动脉高压,CT证实右髂总动脉与下腔静脉间动静脉瘘,行血管内修复后症状缓解,3个月随访无复发。

要点

  • 脊柱术后出现不明原因右心衰竭需警惕医源性动静脉瘘。
  • 腹部连续性杂音是提示髂腔静脉瘘的重要体征。
  • 血管内修复可有效闭合瘘口并逆转高输出量心衰。

核心结论

  • 医源性髂腔静脉瘘致高输出量心衰可通过血管内修复成功治愈,临床结果优异。

研究设计与样本

  • 病例报告:一例35岁女性,脊柱融合术后3年出现进行性呼吸困难和右心衰竭。

主要发现

  • 超声心动图示左室收缩功能正常、右心室增大、功能性三尖瓣反流及中度肺动脉高压。
  • 腹部盆腔CT示右髂总动脉与下腔静脉间动静脉瘘。
  • 血管内修复无围术期并发症,术后数小时症状缓解,3个月随访无症状。

临床怎么用

  • 脊柱术后患者出现右心衰竭和腹部杂音时应行影像学检查排除医源性动静脉瘘。
  • 确诊髂腔静脉瘘后血管内修复是有效治疗选择。

局限性

  • 单个病例报告,结论推广受限。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

The case being presented is a 35-year-old female with a 3-year history of progressive dyspnea and right-sided heart failure following spine surgery. Physical examination identified a continuous bruit in the lower abdomen radiating to her back which prompted further evaluation. Echocardiography showed normal left ventricle systolic function, enlarged right ventricle, functional tricuspid regurgitation, and moderate pulmonary hypertension. A computed tomography (CT) scan of the abdomen and pelvis demonstrated findings consistent with an arteriovenous fistula (AVF) between the right common iliac artery and the inferior vena cava. She underwent an uneventful endovascular repair without perioperative complication. The patient's symptoms resolved a few hours after the procedure and she continued to be symptom free at 3-month follow-up. This case illustrates an iatrogenic iliocaval fistula causing high-output cardiac failure which was successfully treated endovascularly with excellent clinical result.

来源:Ann Vasc Surg,查看原文。版权归原作者所有。

引用

  1. Noland S, Espinoza CA, Dvorak JD, et al. Endovascular Repair of Iatrogenic Iliocaval Fistula Causing High-Output Cardiac Failure after Spine Fusion. Ann Vasc Surg. 2017. PMID: 28647630. doi:10.1016/j.avsg.2017.06.033