纳入400例静脉功能不全患者(419条手术),比较980nm裸尖光纤与1470nm径向尖光纤行大隐静脉腔内激光消融的48个月结果。1470nm组应用能量更低(76.95±15.06 J/cm vs 84.65±13.03 J/cm,P<0.001),48个月再通率更低(8.3% vs 15.9%,P=0.017),且硬结、瘀斑和感觉异常发生率显著更低。

要点

  • 1470nm径向尖光纤能量更低且长期闭塞率更优
  • 980nm裸尖组48个月再通率15.9%高于1470nm组8.3%
  • 980nm裸尖组硬结、瘀斑和感觉异常显著更多

核心结论

  • 980nm与1470nm激光腔内消融均有效治疗大隐静脉功能不全。
  • 1470nm径向尖光纤因能量更低、并发症更少、长期闭塞率更优而更受推荐。

研究设计与样本

  • 研究纳入400例静脉功能不全患者,共419条手术,分为980nm裸尖组(A组)和1470nm径向尖组(B组),每组200例。
  • 随访48个月,于术后第1天、第1周及第1、6、12、24、36、48个月行体格检查和多普勒超声。

主要发现

  • A组应用能量60-120 J/cm(84.65±13.03),B组45-120 J/cm(76.95±15.06),P<0.001,均以15W连续模式。
  • 手术时间A组32.2±9.7分钟,B组31.7±8.8分钟(P=0.47)。
  • 硬结、瘀斑和感觉异常发生率在裸尖激光组显著更高。
  • 深静脉血栓在A组观察到4例。
  • 48个月随访再通率A组15.9%,B组8.3%(P=0.017)。

关键数值与推荐

  • A组平均年龄37.84±12.2岁,B组38.38±12.1岁。
  • 激光光纤插入至隐股交界下方2 cm,回撤速度1-3 cm/秒(2.08±0.6)。
  • 疼痛评估采用Wong-Baker FACES®疼痛量表(0-10分)。

临床怎么用

  • 对于大隐静脉功能不全行腔内激光消融,可优先选择1470nm径向尖光纤以降低能量和并发症。
  • 术后需长期随访监测再通,尤其使用980nm裸尖光纤时。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Varices and venous insufficiency are common and serious health problems in the general population which affect the quality of life. Endothermal treatment of the great saphenous vein has become the first line of treatment for superficial venous reflux, and the endovenous laser ablation (EVLA) method has been widely accepted all over the world. In this method, ablation is provided by a laser fiber inserted into the lumen of the vein. Initially, the fibers were 810 nm, but today the fibers are usually 940, 980, or 1470 nm. METHODS: The study included 400 patients (419 procedures) who were diagnosed with venous insufficiency and underwent 980 and 1470 nm EVLA. Patients were followed up for 48 months. A 980-nm bare-tip laser catheter in Group A and a 1470-nm radial-tip laser catheter in Group B were inserted until they were 2 cm below the saphenofemoral junction. An EVLA catheter was drawn slowly at the rate of 1-3 cm/sec (2.08 ± 0.6). The energy applied to the saphenous vein was 60-120 J/cm (84.65 ± 13.03) and 45-120 J/cm (76.95 ± 15.06) in Group A and Group B, respectively (P < 0.001), with 15 W in the continuous mode. Follow-up visits included a physical examination and Doppler ultrasonography performed at the following time points: day 1, week 1, and months 1, 6, 12, 24, 36, and 48. Saphenous vein occlusion rates and postprocedure saphenous vein diameters were evaluated at each follow-up visit. Pain levels were evaluated using the Wong-Baker FACES® pain scale (0-10). Postoperative complications were recorded. RESULTS: Group A (980 nm laser) consisted of 200 patients with a mean age of 37.84 ± 12.2 years. Group B (1470 nm laser) consisted of 200 patients with a mean age of 38.38 ± 12.1 years. The mean duration of the procedure was 32.2 ± 9.7 min in Group A and 31.7 ± 8.8 min in Group B, respectively (P = 0.47). Induration, ecchymosis, and paresthesia rates were significantly higher in the bare-tip laser group. The most important complication, deep vein thrombosis, was observed in 4 patients in Group A. Recanalization rates were found to be increased by prolonged follow-up periods. At the 48-month follow-up, this rate was 15.9% in Group A and 8.3% in Group B (P = 0.017). This rate showed that the 1470-nm wavelength laser treatment was more successful in Group B than in Group A over the long term. CONCLUSIONS: Both the 980 and 1470 nm wavelength laser-assisted EVLA procedures appear to be effective in treating saphenous vein insufficiency. The 1470-nm radial-tip fiber is preferred due to lower energy levels, lower complication rates, early return to daily life, and the successful long-term occlusion rate.