电磁追踪柔性机器人导管实现辅助导航与自动化血管内导航的体外研究
电磁追踪显著降低平均透视时间和导管子运动次数(均P<.001及P<.02),新型辅助导航进一步缩短后门插管时间(P=.002)并改善左肾动脉插管运动质量(P=.021)。
要点
- 电磁追踪导航可显著减少体外机器人导管插管的透视时间和导管子运动次数。
- 新型辅助导航自动定向导管,缩短后门插管时间并改善左肾动脉运动质量。
- 结果支持3D机器人导管控制联合3D导航提升血管内手术安全与效率。
核心结论
- 电磁追踪联合3D机器人导管控制可提升体外血管内导航的安全性与效率。
- 新型电磁辅助导航自动定向目标,在缩短手术时间和改善导管运动质量方面结果有前景。
研究设计与样本
- 每位使用者用四种可视化模式对左肾动脉和后门两个目标进行插管,比较标准透视与电磁追踪模式。
主要发现
- 电磁追踪显著降低两个插管任务的平均透视时间(P < .001)和导管子运动次数(P < .02)。
- 后门插管中,电磁追踪显著缩短平均插管时间(P < .001)。
- 辅助导航模式(模式3)进一步缩短后门插管时间(P = .002),并改善左肾动脉插管的导管运动质量(P = .021)。
临床怎么用
- 体外结果提示电磁追踪辅助导航可能减少机器人血管内操作的透视暴露并提升导管运动质量。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: Combining three-dimensional (3D) catheter control with electromagnetic (EM) tracking-based navigation significantly reduced fluoroscopy time and improved robotic catheter movement quality in a previous in vitro pilot study. The aim of this study was to expound on previous results and to expand the value of EM tracking with a novel feature, assistednavigation, allowing automatic catheter orientation and semiautomatic vessel cannulation. METHODS: Eighteen users navigated a robotic catheter in an aortic aneurysm phantom using an EM guidewire and a modified 9F robotic catheter with EM sensors at the tip of both leader and sheath. All users cannulated two targets, the left renal artery and posterior gate, using four visualization modes: (1) Standard fluoroscopy (control). (2) 2D biplane fluoroscopy showing real-time virtual catheter localization and orientation from EM tracking. (3) 2D biplane fluoroscopy with novel EM assisted navigation allowing the user to define the target vessel. The robotic catheter orients itself automatically toward the target; the user then only needs to advance the guidewire following this predefined optimized path to catheterize the vessel. Then, while advancing the catheter over the wire, the assisted navigation automatically modifies catheter bending and rotation in order to ensure smooth progression, avoiding loss of wire access. (4) Virtual 3D representation of the phantom showing real-time virtual catheter localization and orientation. Standard fluoroscopy was always available; cannulation and fluoroscopy times were noted for every mode and target cannulation. Quality of catheter movement was assessed by measuring the number of submovements of the catheter using the 3D coordinates of the EM sensors. A t-test was used to compare the standard fluoroscopy mode against EM tracking modes. RESULTS: EM tracking significantly reduced the mean fluoroscopy time (P < .001) and the number of submovements (P < .02) for both cannulation tasks. For the posterior gate, mean cannulation time was also significantly reduced when using EM tracking (P < .001). The use of novel EM assisted navigation feature (mode 3) showed further reduced cannulation time for the posterior gate (P = .002) and improved quality of catheter movement for the left renal artery cannulation (P = .021). CONCLUSIONS: These results confirmed the findings of a prior study that highlighted the value of combining 3D robotic catheter control and 3D navigation to improve safety and efficiency of endovascular procedures. The novel EM assisted navigation feature augments the robotic master/slave concept with automated catheter orientation toward the target and shows promising results in reducing procedure time and improving catheter motion quality.
引用
- Schwein A, Kramer B, Chinnadurai P, et al. Electromagnetic tracking of flexible robotic catheters enables "assisted navigation" and brings automation to endovascular navigation in an in vitro study. J Vasc Surg. 2017. PMID: 28583735. doi:10.1016/j.jvs.2017.01.072
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。