锥形颈与标准EVAR近端失败强烈相关
该回顾性多中心研究纳入156例短颈(<15 mm)且至少一项非长度不良颈(HN)标准的连续EVAR患者,使用Endurant装置。中位随访显示,反向锥形解剖(锥形颈)是近端EVAR失败的独立显著预测因子(P < .012),而宽度>32 mm、角度>60度、钙化或血栓与不良结局无关。
要点
- 锥形颈是标准EVAR近端失败的最强相关因素。
- 其他非长度HN特征(宽度、角度、钙化/血栓)未显示与不良结局相关。
- 颈长<10 mm与10–14 mm亚组间结局无差异。
核心结论
- 在不良解剖中,锥形颈是标准EVAR近端失败唯一显著相关的预测因素。
研究设计与样本
- 回顾性分析2007至2015年三个欧洲学术血管中心156例连续EVAR患者,均短颈(<15 mm)且至少一项非长度HN标准,使用Endurant装置,无额外技术。
主要发现
- 总体EVAR相关死亡率为1.9%(n=3)。
- 总IA型内漏率为5.8%(n=9)。
- 随访期间5例因II型内漏致动脉瘤直径增大并接受二次血管内再干预。
- 中期所有EVAR相关二次手术总数为12例(7.7%)。
- 多因素回归和Cox回归显示反向锥形解剖(锥形颈)是近端EVAR失败的单一显著预测因子(P < .012)。
关键数值与推荐
- 短颈定义为<15 mm。
- 非长度HN标准包括:宽度>32 mm或膨出、角度>60度、反向锥形解剖、周向血栓或钙化>50%。
- 锥形颈与近端EVAR失败显著相关(P < .012)。
- 宽度>32 mm、角度>60度、钙化或血栓与不良结局无显著关联。
临床怎么用
- 在标准EVAR术前评估中,应重视锥形颈的存在,将其视为近端失败的重要风险因素,并独立于肾下颈长度考虑。
局限性
- 回顾性设计,样本量有限(156例),仅使用Endurant装置,随访时间中期。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: Hostile proximal aortic neck (HN) challenges the suitability for standard endovascular aneurysm repair (EVAR) of patients at high risk for "open" repair. However, there has been little if any focus placed on the individual role of the "nonlength" HN features in EVAR outcomes. The aim of this study was to evaluate their individual and potentially predictive role in outcomes of EVAR under HN conditions. METHODS: Data of 156 consecutive EVAR patients with short (<15 mm) HN, treated with the Endurant device (Medtronic Cardiovascular, Santa Rosa, Calif) at three European academic vascular centers between 2007 and 2015, were collected and retrospectively analyzed. All patients had at least one of the four well-known nonlength HN criteria (width >32 mm or bulge, angulation >60 degrees, reverse taper anatomy, and circumferential thrombus or calcification >50%) and underwent standard EVAR without additional techniques, such as use of chimney grafts or endoanchors. Primary end points were absence of type IA endoleak at 1 month and midterm follow-up and aneurysm sac stabilization or shrinkage. Secondary end points were 30-day mortality, overall survival, and secondary interventions related to EVAR. The study cohort was classified in two subgroups related to neck length (length <10 mm and length between 10 and 14 mm) as well as in two subgroups according to on-label or off-label stent graft use. RESULTS: Mean clinical and radiologic follow-up was 41.1 ± 24.7 and 31.7 ± 19.0 months, respectively. Overall EVAR-related mortality was 1.9% (n = 3). The total type IA endoleak rate was 5.8% (n = 9). In four patients, the type IA endoleak was detected intraoperatively and solved by endovascular means. A type IA endoleak was detected in three patients at 1 month and in two patients at 2-year follow-up. During follow-up, five patients showed an increase of aneurysm diameter due to type II endoleak and were treated by secondary endovascular reinterventions. The total number of all EVAR-related secondary procedures in the midterm was 12 (7.7%). Univariate analysis showed that the center of treatment and the clinical or anatomic features were not associated with adverse outcomes. Multiple regression and Cox regression analysis of HN features revealed that reverse taper anatomy (conical neck) was the single and significantly associated predictor of proximal EVAR failure (P < .012). Width >32 mm, angulation >60 degrees, and calcification or thrombus were not associated with adverse outcomes. Analysis between HN length cohorts and between on-label and off-label subgroups revealed no difference in outcomes. CONCLUSIONS: A conical neck in hostile anatomies represents the single strongest factor associated with proximal failure of standard EVAR. This finding should be considered and highlighted apart from the length of the infrarenal neck to prevent midterm failure of standard EVAR.
引用
- Pitoulias GA, Valdivia AR, Hahtapornsawan S, et al. Conical neck is strongly associated with proximal failure in standard endovascular aneurysm repair. J Vasc Surg. 2017. PMID: 28583728. doi:10.1016/j.jvs.2017.03.440
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。