本研究用计算流体力学比较颈动脉内膜切除术后补片移植与直接缝合的血流动力学,发现补片组振荡剪切指数和相对 Residence 时间更高、扰动流区域更广,直接缝合在特定条件下未产生不利血流动力学。

要点

  • 补片移植组OSI和RRT均高于直接缝合组,扰动流区域更广。
  • 直接缝合在颈总动脉和/或颈动脉球部或ICA直径>5.0 mm时未见不利血流动力学。
  • 补片移植不区分颈动脉直径使用时计算值绝对更高。

核心结论

  • 补片移植相比直接缝合导致更高的OSI和RRT值及更广的扰动流区域。
  • 直接缝合在特定条件下未产生可能影响长期结局的不利血流动力学。

研究设计与样本

  • 对12例(13条颈动脉)因狭窄>70%手术患者进行计算流体力学分析,其中9条用补片移植,4条用直接缝合。
  • 血流条件使用来自多普勒超声的患者特异性边界条件和来自磁共振血管造影的几何模型。

主要发现

  • 补片移植组空间平均OSI均值为0.07,直接缝合组为0.03。
  • 补片移植组OSI超过阈值0.2的面积百分比为10.1%,直接缝合组为3.7%。
  • 补片移植组空间平均RRT均值为4.4 1/Pa,直接缝合组为1.6 1/Pa。
  • 补片移植组RRT超过阈值4 1/Pa的面积百分比为22.5%,直接缝合组为6.5%。

关键数值与推荐

  • OSI阈值0.2:补片移植组超阈值面积10.1%,直接缝合组3.7%。
  • RRT阈值4 1/Pa:补片移植组超阈值面积22.5%,直接缝合组6.5%。
  • 直接缝合在颈总动脉和/或颈动脉球部或ICA直径>5.0 mm时未产生不利血流动力学。

临床怎么用

  • 直接缝合在颈总动脉和/或颈动脉球部或ICA直径>5.0 mm时可考虑,不产生不利血流动力学。
  • 补片移植不区分颈动脉直径使用时计算值绝对更高,应谨慎选择。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Closure technique after carotid endarterectomy (CEA) still remains an issue of debate. Routine use of patch graft (PG) has been advocated to reduce restenosis, stroke, and death, but its protective effect, particularly from late restenosis, is less evident and recent studies call into question this thesis. This study aims to compare PG and direct suture (DS) by means of computational fluid dynamics (CFD). To identify carotid regions with flow recirculation more prone to restenosis development, we analyzed time-averaged oscillatory shear index (OSI) and relative residence time (RRT), that are well-known indices correlated with plaque formation. METHODS: CFD was performed in 12 patients (13 carotids) who underwent surgery for stenosis >70%, 9 with PG, and 4 with DS. Flow conditions were modeled using patient-specific boundary conditions derived from Doppler ultrasound and geometries from magnetic resonance angiography. RESULTS: Mean value of the spatial averaged OSI resulted 0.07 for PG group and 0.03 for DS group, the percentage of area with OSI above a threshold of 0.2 resulted 10.1% and 3.7%, respectively. The mean of averaged-in-space RRT values was 4.4 1/Pa for PG group and 1.6 1/Pa for DS group, the percentage of area with RRT values above a threshold of 4 1/Pa resulted 22.5% and 6.5%, respectively. CONCLUSIONS: Both OSI and RRT values resulted higher when PG was preferred to DS and also areas with disturbed flow resulted wider. The absolute higher values computed by means of CFD were observed when PG was used indiscriminately regardless of carotid diameters. DS does not seem to create negative hemodynamic conditions with potential adverse effects on long-term outcomes, in particular when CEA is performed at the common carotid artery and/or the bulb or when ICA diameter is greater than 5.0 mm.