血管内超声验证外周动脉钙化造影评分系统
本研究以血管内超声(IVUS)为金标准,验证PARC、PACSS和DEFINITIVE Ca++三种造影钙化评分系统。47例患者中IVUS检出钙化44例(93.6%),造影仅检出26例(55.3%)(p<0.001)。随造影钙化严重度增加,IVUS表浅钙化最大弧度和长度逐步增加,但深部钙化无此趋势。
要点
- 造影对钙化检出敏感性仅59%,但特异性100%。
- 造影钙化评分加重时,IVUS表浅钙化弧度和长度逐步增加。
- 三种评分系统可用于分类外周动脉钙化,尤其表浅钙化。
核心结论
- IVUS证实PARC、PACSS和DEFINITIVE Ca++评分系统可用于分类外周动脉疾病钙化程度,尤其表浅钙化。
研究设计与样本
- 研究采用JetStream G3 Calcium Study中47例患者(中位年龄72岁;34名男性)的术前造影和IVUS数据,验证三种造影钙化评分系统。
主要发现
- IVUS检出钙化44/47(93.6%),造影检出26/47(55.3%)(p<0.001)。
- 造影相对IVUS的敏感性、特异性、阳性预测值、阴性预测值分别为59%、100%、100%、14%。
- PARC标准下,随钙化严重度增加,IVUS最大钙化弧度从无钙化的120°增至严重钙化的305°(p<0.001),钙化长度从7 mm增至68 mm(p<0.001)。
- PACSS和DEFINITIVE Ca++评分系统也观察到类似趋势。
关键数值与推荐
- PARC钙化严重度分为无、局灶、轻度、中度、重度;PACSS分为0至4级;DEFINITIVE Ca++分为无、中度、重度。
- IVUS钙化位置分类为表浅、深部或混合。
临床怎么用
- 造影钙化评分可用于评估外周动脉钙化严重度,尤其表浅钙化,但造影低估钙化检出,敏感性59%。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To validate 3 angiographic scoring systems for peripheral artery calcification using intravascular ultrasound (IVUS) as the gold standard. METHODS: The study employed preprocedure angiography and IVUS data from 47 patients (median age 72 years; 34 men) in the 55-patient JetStream G3 Calcium Study ( ClinicalTrials.gov identifier NCT01273623) to validate the 3 angiographic scoring systems [Peripheral Academic Research Consortium (PARC), Peripheral Arterial Calcium Scoring System (PACSS), and the DEFINITIVE Ca++ trial]. Preprocedure angiograms were analyzed using conventional quantitative vessel analysis software in 2 orthogonal views. Calcium length was evaluated by markers placed beside the artery during the procedure; calcium deposit(s) were assessed as being on one or both sides of the vessel wall. The 3 calcium scoring systems used these 2 basic angiographic elements to evaluate calcium severity. Based on these criteria, calcium severity varied from none to focal, mild, moderate, or severe in PARC; grade 0 to 4 in PACSS; and none, moderate, or severe in the DEFINITIVE Ca++ system. Calcium location on IVUS was classified as superficial, deep, or mixed. Lesion length was the segment between the most normal looking proximal and distal reference sites. Superficial, deep, and calcium length were based on motorized IVUS pullback. RESULTS: IVUS detected calcium in 44/47 (93.6%) lesions, and angiography detected calcium in 26/47 (55.3%) lesions (p<0.001). The sensitivity, specificity, positive predictive value, and negative predictive value of angiography relative to IVUS were 59%, 100%, 100%, and 14%, respectively. With increasing severity of angiographic calcium, there was a stepwise increase in the prevalence of IVUS superficial calcium and the maximum arc and length of superficial calcium. Using PARC criteria, with increasing severity of calcification, IVUS maximum calcium arc increased from 120° for none to 305° for severe (p<0.001); the length of calcium increased from 7 to 68 mm (p<0.001). Though a similar trend was seen in IVUS superficial calcium, it was not observed in IVUS deep calcium. Similar observations were seen when using the PACSS and DEFINITIVE Ca++ scoring systems. CONCLUSION: IVUS confirmed that the PARC, PACSS, and DEFINITIVE Ca++ calcium scoring systems can be used to classify the degree of calcium in peripheral artery disease, especially superficial calcium.
引用
- Yin D, Maehara A, Shimshak TM, et al. Intravascular Ultrasound Validation of Contemporary Angiographic Scores Evaluating the Severity of Calcification in Peripheral Arteries. J Endovasc Ther. 2017. PMID: 28504047. doi:10.1177/1526602817708796
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。