文献速递主动脉疾病

双烟囱技术治疗主动脉弓疾病的首次经验

First experience with the double chimney technique in the treatment of aortic arch diseases.
PubMed 文献 · J Vasc Surg · 2017-05-11

所有患者弓部病变均被覆盖,弓上分支通畅,围术期无死亡,但出现3例(13.0%)I型内漏及烟囱支架移位或受压各1例(4.3%)。中位随访28.0±19.8个月,无TEVAR相关死亡。

要点

  • 双烟囱技术重建弓上分支安全微创,围术期死亡率低。
  • 主要围术期并发症为I型内漏和头臂干烟囱支架受压。
  • 长期疗效与耐久性仍需更多经验评估。

核心结论

  • 采用双烟囱技术行TEVAR重建弓上分支安全、微创,术后死亡率低。
  • 主要围术期并发症包括I型内漏和头臂干烟囱支架受压。

研究设计与样本

  • 纳入急性主动脉夹层20例、主动脉弓动脉瘤2例、TEVAR术后I型内漏1例。
  • 仅1例急性主动脉夹层因严重左下肢缺血行急诊手术。
  • TEVAR术后2周、3和6个月及此后每年行CT随访。

主要发现

  • 所有患者主动脉弓病变均被覆盖,弓上分支通畅,无相关并发症。
  • 22例重建头臂干和左颈总动脉,近端锚定区位于0区;1例重建左颈总动脉和左锁骨下动脉。
  • 术中发生3例(13.0%)I型内漏。
  • 围术期烟囱支架移位1例(4.3%),TEVAR后4天烟囱支架受压1例(4.3%)。
  • 无II型内漏及围术期死亡,中位随访28.0±19.8(范围3-84)个月,无TEVAR相关死亡。

临床怎么用

  • 双烟囱技术可作为重建弓上分支的微创替代方案,适用于相关主动脉弓疾病患者。
  • 术后需密切监测I型内漏及头臂干烟囱支架受压情况。

局限性

  • 样本量小(23例),随访时间有限,长期疗效和耐久性尚需更多经验评估。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: The objective of this study was to summarize our initial experience using the double chimney technique to treat aortic arch diseases. METHODS: From December 2009 to October 2016, 23 patients with aortic arch diseases, including 20 acute aortic dissections, 2 aortic arch aneurysms, and 1 type I endoleak after thoracic endovascular aortic repair (TEVAR), were treated using a double chimney technique. An emergent operation was performed in only one patient with an acute aortic dissection for severe left lower extremity ischemia. All patients were observed after TEVAR with computed tomography scans at 2 weeks, at 3 and 6 months, and annually thereafter. RESULTS: In all patients, aortic arch lesions were covered, and supra-aortic branches were patent without morbidity. In 22 patients, the innominate artery (IA) and left common carotid artery were reconstructed with the proximal landing zone in zone 0; in 1 patient, the left common carotid artery and left subclavian artery were reconstructed. During the procedure, there were three (13.0%) type I endoleaks. Chimney stent graft migration occurred in one (4.3%) patient perioperatively; compression of a chimney stent graft occurred in one (4.3%) patient 4 days after TEVAR. There were no type II endoleaks or perioperative mortality. Median follow-up was 28.0 ± 19.8 (range, 3-84) months, with no TEVAR-related deaths. Partial compression of the chimney stent graft in the IA occurred at 3 months after TEVAR in one (4.3%) patient; three patients had persistent but asymptomatic type I endoleaks. CONCLUSIONS: TEVAR using a double chimney technique to reconstruct the supra-aortic branches provides a safe and minimally invasive alternative procedure associated with low postoperative mortality. The main perioperative complications include type I endoleak and compression of the chimney stent grafts in the IA. More experience with long-term results is needed to evaluate the effectiveness and durability of this advanced endovascular procedure.

来源:J Vasc Surg,查看原文。版权归原作者所有。

引用

  1. Wang T, Shu C, Li QM, et al. First experience with the double chimney technique in the treatment of aortic arch diseases. J Vasc Surg. 2017. PMID: 28502544. doi:10.1016/j.jvs.2017.02.035

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。