现成支架移植物腔内修复破裂性胸腹主动脉瘤:首例报告
本文报告首例使用现成Cook T-Branch支架移植物腔内修复破裂性3型胸腹主动脉瘤。患者68岁,急诊行腔内修复,手术330分钟,术后无心血管事件,远端灌注良好且疼痛完全缓解。作者认为该现成支架是治疗破裂性TAAA3的有效选择。
要点
- 现成T-Branch支架可在急诊情况下立即使用,无需定制等待。
- 腔内修复破裂性TAAA3可行,但需警惕脊髓缺血风险。
- 本例预防性行脑脊液引流,术后无心血管事件且疼痛完全缓解。
核心结论
- 现成Cook T-Branch支架移植物是治疗破裂性3型胸腹主动脉瘤的有效选择,为首例成功报告。
研究设计与样本
- 病例报告:1例68岁男性破裂性TAAA3患者,急诊行腔内修复术。
主要发现
- 手术在全麻下于杂交手术室进行,使用34×18×202 mm T-Branch移植物,耗时330分钟,过程顺利。
- 术后即刻无心血管事件,远端灌注良好,疼痛完全缓解。
- 因胸主动脉被覆盖存在脊髓缺血高风险,决定行脑脊液引流。
关键数值与推荐
- 传统开放手术治疗TAAA3的死亡率为8%至25%。
- 现成T-Branch支架可使约83%的患者获得即刻治疗。
- 分支支架选择无共识,本例选用覆膜支架基于其柔顺性和与动脉长度的兼容性。
临床怎么用
- 对于破裂性TAAA3,现成T-Branch支架可紧急使用,无需等待定制,适合急诊腔内修复。
- 覆盖胸主动脉时需评估脊髓缺血风险,可考虑脑脊液引流。
- 分支支架选择需根据柔顺性和血管长度个体化决定。
局限性
- 单例病例报告,结论推广受限。
- 分支支架选择尚无共识,本例经验需进一步验证。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Thoracoabdominal aortic aneurysm type 3 (TAAA3) is a challenging disease to vascular surgeons. In these cases, the best treatment methodology is conventional surgery, which portends a mortality rate ranging from 8% to 25%. Endovascular treatment has been shown to be a good alternative, with encouraging results. In 2012, a new alternative for endovascular treatment of TAAA3 was presented: Cook T-Branch endoprosthesis (Cook Medical, Bloomington, Indiana). We present the first successful case of endovascular treatment of a ruptured TAAA3 with this stent. CASE REPORT: A 68-year-old was admitted to the emergency department with epigastric pain, radiating to the back without improvement with opioids. Physical examination revealed an epigastric pulsatile mass without evidence of peritonitis or blows. The patient was known to have a thoracoabdominal aortic aneurysm. A computed tomography angiography showed growth of the abdominal aneurysm, accompanied with signs of rupture (fat blurring in the posterior region of TAAA3). The patient was submitted to endovascular repair of a ruptured TAAA3 in a hybrid operating room using a 34 × 18 × 202 mm T-Branch graft. It was an uneventful 330-min procedure under general anesthesia. Immediate postoperative period had no cardiovascular events. Evolution showed excellent distal perfusion and complete pain relief. CONCLUSIONS: Until now, the only endovascular alternative for ruptured aortic aneurysm was the parallel prosthesis technique. The development of an off-the-shelf T-Branch prosthesis (Cook Medical) has solved this problem in many cases, enabling immediate treatment of this type of aneurysm in approximately 83% of patients. The fact that the thoracic aorta would be excluded lead the patient to a high risk of spinal cord ischemia. We therefore decided to make a cerebrospinal fluid drainage. There is no consensus regarding the best devices to be used as branches. In this case, we chose to use the previously described covered stents, according to its flexibility and compatibility with the length of arteries. This is the first report of the use of a T-branch (Cook Medical) for treatment of a ruptured TAAA3. The development of an off-the-shelf endoprosthesis has many advantages: it is available for use in an emergency situation, and there is no time lapse for its preparation. The T-Branch stent graft is a valid option for the treatment of ruptured TAAA3.
引用
- Wolosker N, Fioranelli A, Ferreira M, et al. Endovascular Repair of Ruptured Thoracoabdominal Aortic Aneurysm with an Off-the-shelf Endoprosthesis. Ann Vasc Surg. 2017. PMID: 28478177. doi:10.1016/j.avsg.2017.02.013
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。