文献速递主动脉疾病

专项监测计划提高EVAR术后随访依从性

A Dedicated Surveillance Program Improves Compliance with Endovascular Aortic Aneurysm Repair Follow-up.
PubMed 文献 · Ann Vasc Surg · 2017-05-10

BACKGROUND: Current recommendations suggest lifetime follow-up for endovascular aortic aneurysm repair (EVAR) patients to avoid consequences associated with endoleak and aneurysm enlargement.…

要点

  • 专项监测计划使EVAR术后随访完成率达82.3%。
  • 13.3%患者接受二次干预,首次干预中位时间476天。
  • 无动脉瘤相关死亡,但总体死亡率为24.6%。

核心结论

  • 通过专项计划进行规律EVAR术后监测可获得高随访依从性、13.3%二次干预率和低动脉瘤相关死亡率。

主要发现

  • 425例(82.3%)完成监测,平均随访影像检查4.2±2.9次,首次随访中位时间36天。
  • 二次干预患者平均影像检查6.1±3.9次,无二次干预患者平均3.4±2.3次(P < 0.001)。
  • 总体死亡率24.6%(n = 127),其中不明原因死亡32例(6.2%),非EVAR相关死亡95例(18.3%),无动脉瘤相关死亡。

临床怎么用

  • EVAR术后应坚持终身规律影像监测和医生审核,专项通知计划有助于提高随访完成率。

局限性

  • 单中心回顾性研究,结果可能受中心实践和患者群体影响。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Current recommendations suggest lifetime follow-up for endovascular aortic aneurysm repair (EVAR) patients to avoid consequences associated with endoleak and aneurysm enlargement. Follow-up compliance has been reported between 43% and 92%, with most single-center studies citing successful follow-up surveillance at less than 60%. We investigated follow-up completeness with a defined surveillance program and subsequent secondary intervention prevalence from a single center. METHODS: Our surveillance program notified patients of the need for follow-up imaging and surgeon review. Data were obtained from retrospective review of a prospective database, including operative and follow-up details, follow-up imaging completeness, endoleak incidence, and secondary intervention prevalence. RESULTS: Five hundred seventeen patients received elective EVAR from 2005 to 2015. Surveillance was achieved in 425 (82.3%). Mean number of follow-up studies was 4.2 ± 2.9 and median time to first follow-up was 36 days. Four hundred forty-eight patients (86.7%) had freedom from intervention. Sixty-nine unique patients (13.3%) had 107 secondary interventions. Median time to first secondary intervention in 69 patients was 476 days. Mean number of imaging studies for secondary intervention patients was 6.1 ± 3.9, compared with mean 3.4 ± 2.3 for patients without (P < 0.001). Overall mortality was 24.6% (n = 127), including 32 deaths of unknown cause (6.2% overall) and 95 of non-EVAR-related causes (18.3%). No aneurysm-related deaths were reported. CONCLUSIONS: Regular post-EVAR surveillance through a dedicated program resulted in a high rate of follow-up compliance, 13.3% rate of secondary intervention, and low aneurysm-related mortality. Careful lifetime surveillance remains important in long-term care following elective EVAR.

来源:Ann Vasc Surg,查看原文。版权归原作者所有。

引用

  1. Cohen J, Pai A, Sullivan TM, et al. A Dedicated Surveillance Program Improves Compliance with Endovascular Aortic Aneurysm Repair Follow-up. Ann Vasc Surg. 2017. PMID: 28501665. doi:10.1016/j.avsg.2017.04.045

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。