医师改良Anaconda支架腔内修复短颈腹主动脉瘤
本文报告一例81岁女性,腹主动脉瘤直径79mm、瘤颈短且髂动脉严重迂曲,因开放手术高风险且标准腔内修复不适用,采用医师改良Anaconda支架(左肾动脉开窗)完成腔内修复。术后过程顺利,1年CT显示瘤囊完全隔绝、左肾动脉通畅。
要点
- 短颈、迂曲髂动脉的腹主动脉瘤可考虑医师改良开窗支架。
- Anaconda支架柔顺性适合严重髂动脉迂曲的腔内修复。
- 术后1年CT证实瘤囊完全隔绝且左肾动脉通畅。
核心结论
- 医师改良Anaconda支架开窗技术可用于短颈腹主动脉瘤的腔内修复。
研究设计与样本
- 个案报道:81岁女性腹主动脉瘤患者,瘤径79mm,短颈,髂动脉严重迂曲。
主要发现
- 术后过程顺利,1年CT示瘤囊完全隔绝、左肾动脉通畅。
临床怎么用
- 对开放手术高风险且标准腔内修复不适用(短颈)者,可考虑医师改良开窗支架。
- 严重髂动脉迂曲时优先选择柔顺性好的支架。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
An 81-year-old woman was referred for the treatment of a 79-mm-diameter short neck abdominal aortic aneurysm with highly tortuous iliac arteries. She was considered at high risk for open repair and not suitable for standard endovascular repair given the short length of the proximal neck. Delay for a manufactured custom-made fenestrated stent graft was too long given the diameter of the aneurysm. A flexible stent graft was preferred because of severe iliac tortuosity. Endovascular repair was performed using a physician-modified Anaconda stent graft with 1 fenestration for the left renal artery. The technique for device modification and implantation is described. Postoperative course was uneventful and 1-year computed tomography scan showed complete exclusion of the aneurysm sac and patent left renal artery.
引用
- Duprey A, Ben Ahmed S, Millon A, et al. Endovascular Repair of a Short Neck Abdominal Aortic Aneurysm with a Physician-Modified Vascutek Anaconda Stent Graft. Ann Vasc Surg. 2017. PMID: 28495541. doi:10.1016/j.avsg.2017.04.043
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。