支架移植物部署增加离体猪主动脉僵硬度
本研究在离体猪胸主动脉搏动模型中评估TEVAR对主动脉僵硬度的影响,测量基线及支架部署后的脉搏波速度(PWV)。结果显示近端支架部署后PWV增加4%(P=0.09),支架延伸后增加18%(P<0.001),非支架段脉压也显著升高,且PWV与脉压升高与支架覆盖比例呈正相关。
要点
- 离体猪主动脉模型中,支架延伸后PWV增加18%
- 非支架段脉压升高与支架覆盖比例正相关
- TEVAR导致主动脉血流动力学显著改变
核心结论
- 在离体猪主动脉模型中,支架移植物部署后主动脉僵硬度增加,且依赖于支架覆盖主动脉的比例。
主要发现
- 基线平均主动脉PWV为5.0 m/s。
- 近端支架部署后PWV增加4%(P=0.09),支架延伸后增加18%(P<0.001)。
- 非支架升主动脉脉压在近端支架部署后增加11.0±1.2 mm Hg(P<0.001),支架延伸后增加17.3±1.5 mm Hg(P<0.001)。
- PWV和脉压的增加与支架覆盖百分比呈正线性相关(P<0.001和P<0.001)。
临床怎么用
- TEVAR导致主动脉血流动力学显著改变,值得在临床环境中评估。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Aortic stiffness is an independent predictor of cardiovascular mortality. In this study, the effect of thoracic endovascular aortic repair (TEVAR) on aortic stiffness is investigated by measuring aortic pulse wave velocity (PWV) in an ex vivo porcine model. METHODS: Fifteen fresh porcine thoracic aortas were connected to a benchtop pulsatile system. Intraluminal pressures were recorded in the ascending aorta and at the celiac trunk using a needle connected to a pressure sensor. The distance between the needles was divided by the time difference between the base of the pressure peaks to calculate aortic PWV at baseline and after stent-graft deployment and distal stent-graft extension. RESULTS: Mean aortic PWV was 5.0 m/s at baseline. PWV increased by 4% after proximal stent-graft deployment (P = 0.09) and by 18% after stent-graft extension (P < 0.001). Pulse pressure in the nonstented ascending aorta increased by 11.0 ± 1.2 mm Hg after proximal stent-graft deployment (P < 0.001) and by 17.3 ± 1.5 mm Hg after stent-graft extension (P < 0.001). The increases in PWV and pulse pressure showed a positive linear correlation with the percentage of stent-graft coverage (P < 0.001 and P < 0.001). CONCLUSIONS: In this experimental setup, aortic stiffness increased after stent-graft deployment, dependent on the percentage of the aorta that was covered by stent graft. These results show that TEVAR leads to significant changes in aortic hemodynamics, which merits evaluation in the clinical setting.
引用
- de Beaufort HWL, Conti M, Kamman AV, et al. Stent-Graft Deployment Increases Aortic Stiffness in an Ex Vivo Porcine Model. Ann Vasc Surg. 2017. PMID: 28483612. doi:10.1016/j.avsg.2017.04.024
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。