文献速递主动脉疾病

B型主动脉夹层开窗位置选择:离体研究

Where to Fenestrate in Aortic Dissection Type B? An Ex Vivo Study.
PubMed 文献 · Ann Vasc Surg · 2017-05-04

本研究在6个猪离体B型主动脉夹层模型中比较近端与远端开窗对假腔体积(FLV)的影响。远端开窗使全部3个模型FLV下降,近端开窗2/3模型FLV增加;远端开窗组FLV缩减显著优于近端组(9.6±3.5% vs. 0.7±2.9%,P=0.03)。

要点

  • 远端开窗在离体模型中使假腔体积下降。
  • 远端开窗假腔缩减优于近端开窗(P=0.03)。
  • 近端开窗多数模型假腔体积增加。

核心结论

  • 在离体B型主动脉夹层模型中,远端开窗带来最大假腔缩减。

研究设计与样本

  • 在离体猪主动脉制造人工B型夹层,共6个模型。
  • 将夹层内膜片分为近、中、远三等份,分别于近端或远端中心开窗。
  • 模型置于经验证的体外搏动流循环系统,用CT测量真腔与假腔体积。

主要发现

  • 近端开窗组3个模型中2个假腔体积增加。
  • 远端开窗组3个模型假腔体积均下降。
  • 远端开窗组假腔缩减显著优于近端组(9.6±3.5% vs. 0.7±2.9%,P=0.03)。

临床怎么用

  • 离体证据提示B型夹层开窗宜优先考虑远端位置以促进假腔缩减。

局限性

  • 研究为离体猪模型,样本量小(共6个模型),结果需临床验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Fenestration is a minimally invasive alternative for the treatment of acute symptomatic aortic dissections because it may quickly decrease the pressure gradient of the false lumen. It remains unclear where the optimal location of these fenestrations should be chosen. The purpose of this study was to study false lumen volume (FLV) after different fenestration strategies in porcine ex vivo models of aortic type B dissection. METHODS: An artificial dissection was created in ex vivo porcine aortas. A total number of 6 aortic dissection models were made. The dissection flap was divided in 3 equal parts; proximal, mid, and distal sections. In 3 models, a fenestration was made in the center of the proximal section of the dissection flap. In the 3 others in the center of the distal part of the dissection flap. The aorta was positioned in a validated in vitro circulatory system with physiological pulsatile flow. Volume measurements of true lumen volume and FLV were assessed with computed tomography. RESULTS: Performing a fenestration in the proximal part of the dissection flap resulted in FLV increase in 2 of the 3 models. Performing a fenestration in the distal part of the dissection flap resulted in FLV decrease in all 3 models. False lumen reduction was obtained significantly in the distally fenestrated models compared to the proximally fenestrated models (9.6 ± 3.5% vs. 0.7 ± 2.9%, P = 0.03). CONCLUSIONS: In this ex vivo study, we showed that distal fenestration of the false lumen in aortic dissection will result in the largest false lumen reduction.

来源:Ann Vasc Surg,查看原文。版权归原作者所有。

引用

  1. Veger HTC, Pasveer EH, Visser MJT, et al. Where to Fenestrate in Aortic Dissection Type B? An Ex Vivo Study. Ann Vasc Surg. 2017. PMID: 28478168. doi:10.1016/j.avsg.2017.03.170