EVAR术中应用Amplatzer血管塞4行肠系膜下动脉栓塞的创新技术
本研究介绍了一种在EVAR术中经股动脉入路、仅用常规EVAR器械行肠系膜下动脉栓塞的简易快速技术,使用DrySeal鞘和AVP4完成操作。33例中技术成功率90.9%(30/33),中位手术时间11.6分钟,无因IMA栓塞导致的并发症。
要点
- 经股动脉入路使用DrySeal鞘辅助IMA插管,结合支架移植物球囊使AVP4精准放置于IMA根部。
- 技术成功率90.9%(30/33例),中位手术时间11.6分钟。
- 无因IMA栓塞导致的并发症,操作安全快速。
核心结论
- 该技术可经股动脉入路安全快速地将AVP4放置于IMA内,解决了传统上被视为困难的插管问题。
研究设计与样本
- 技术描述性研究,共33例在EVAR术中行IMA栓塞,采用经股动脉入路和常规EVAR器械。
主要发现
- 技术成功率为90.9%(30/33例)。
- 中位手术时间为11.6分钟。
- 未观察到因IMA栓塞导致的并发症。
关键数值与推荐
- 使用16F或18F DrySeal鞘从股动脉插入至IMA附近。
- 采用内径0.038英寸的血管造影导管进行IMA插管。
- 使用Amplatzer血管塞4(AVP4)进行栓塞。
临床怎么用
- 在EVAR术中可经股动脉入路使用常规器械行IMA栓塞,无需额外入路。
- DrySeal鞘与支架移植物球囊结合有助于AVP4精准放置于IMA根部。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: The aim of this study is to present an easy and quick technique for embolization of the inferior mesenteric artery (IMA) during endovascular aneurysm repair (EVAR). TECHNIQUE: We performed IMA embolization using a conventional EVAR device alone with the femoral artery approach during EVAR, which has not been reported previously. First, a 16F or 18F DrySeal Sheath is inserted from the femoral artery into the site around the IMA. Second, cannulation is performed in the IMA with an angiography catheter having a 0.038-inch inner lumen that is used for gate cannulation during EVAR. Third, IMA embolization is performed using the Amplatzer Vascular Plug 4 (AVP4). The use of the DrySeal Sheath facilitates cannulation of the IMA, and its combination with a stent-graft balloon allows the AVP4 to be placed at the root of the IMA without deviation of the catheter. The success rate of the procedure was 90.9% (30/33 cases). The median procedure time was 11.6 min. No complications due to IMA embolization were noted. CONCLUSION: This procedure enables safe and quick placement of the AVP4 in the IMA using the catheter insertion approach from the femoral artery, which has been conventionally regarded as difficult.
引用
- Morikage N, Samura M, Takeuchi Y, et al. Innovative Procedure for Inferior Mesenteric Artery Embolization Using the Amplatzer Vascular Plug 4 during Endovascular Aneurysm Repair. Ann Vasc Surg. 2017. PMID: 28499863. doi:10.1016/j.avsg.2017.03.181
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。