文献速递主动脉疾病

「圈套器搭载」技术:分支型腔内主动脉修复中目标血管插管的补救技巧

"Snare-Ride": A Bailout Technique to Catheterize Target Vessels With Unfriendly Anatomy in Branched Endovascular Aortic Repair.
PubMed 文献 · J Endovasc Ther · 2017-05-18

本文介绍一种新型腔内补救技术「圈套器搭载」,用于胸腹主动脉瘤(TAAA)分支型支架修复中标准插管困难时完成目标血管支架置入。技术经腋窝入路插管支架分支,经股动脉入路插管目标血管,用圈套器捕获并推送腋窝导丝进入目标血管,随后常规顺行桥接。结论认为该技术对困难解剖目标血管插管有用,早期经验显示安全可行。

要点

  • 标准插管困难时可用圈套器搭载技术完成目标血管插管
  • 技术经腋窝和股动脉双入路,圈套器捕获并推送导丝
  • 早期经验显示安全可行,但需更多验证

核心结论

  • 圈套器搭载技术可作为TAAA分支支架修复中困难解剖目标血管插管的补救方法,早期经验显示安全可行。

研究设计与样本

  • 技术描述类文章,介绍一种新型腔内补救技术,未报告样本量或研究设计细节。

主要发现

  • 使用现成分支支架(如标准四分支装置)时,尤其解剖不完美匹配时,预计会出现技术困难。
  • 该技术经腋窝入路插管支架分支,经股动脉入路插管目标血管,圈套器捕获并推送导丝进入目标血管,随后常规顺行桥接。

临床怎么用

  • 在TAAA分支支架修复中,标准插管技术失败且解剖困难时,可考虑采用圈套器搭载技术完成目标血管插管和支架置入。

局限性

  • 早期经验,安全性和可行性需进一步研究验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To describe a novel endovascular bailout technique for successful completion of target vessel stenting during branched stent-graft repair of thoracoabdominal aortic aneurysms (TAAA) after encountering difficulties with standard catheterization techniques. TECHNIQUE: Technical difficulties when using fenestrated and branched grafts should be expected, especially in difficult anatomy or when an off-the-shelf device (eg, standard 4-branch device) is used that does not perfectly "match" the anatomy. The "snare-ride technique" facilitates antegrade transaxillary side branch catheterization and stent placement during TAAA branched grafting using a snare via a transfemoral approach. The branch of the graft is catheterized from an axillary access. The respective target vessel is then catheterized via a femoral access. An Indy snare is advanced over the transfemoral wire and positioned near the entrance of the target vessel. The transaxillary wire inside the branch of the graft is then advanced, snared, and pushed inside the target vessel with the snare. The procedure is thereafter continued with antegrade bridging of the target vessel in routine fashion. CONCLUSION: The snare-ride technique can be a useful maneuver to catheterize target vessels with difficult anatomy in TAAA branched stent-graft repair. Early experience shows safety and feasibility.

来源:J Endovasc Ther,查看原文。版权归原作者所有。

引用

  1. Ferreira M, Katsargyris A, Rodrigues E, et al. "Snare-Ride": A Bailout Technique to Catheterize Target Vessels With Unfriendly Anatomy in Branched Endovascular Aortic Repair. J Endovasc Ther. 2017. PMID: 28514896. doi:10.1177/1526602817709465

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。