多层平行腔内移植物技术紧急修复严重成角胸腹主动脉瘤
本文描述一例76岁男性严重慢性阻塞性肺疾病和冠心病患者,因症状性9 cm IV型胸腹主动脉瘤接受紧急全腔内修复。因主动脉和髂动脉严重成角且肠系膜上动脉与腹腔干共干,采用双侧股动脉和单侧肱动脉入路的多层平行腔内移植物技术,患者恢复良好,术后CT显示内脏和肾动脉支架通畅、动脉瘤完全隔绝且无内漏。
要点
- 严重成角的胸腹主动脉瘤可通过多层平行腔内移植物技术实现紧急全腔内修复。
- 双侧股动脉和单侧肱动脉入路结合「buddy」导丝和「body-floss」技术可矫正主动脉和髂动脉成角。
- 术后CT显示内脏和肾动脉支架通畅、动脉瘤完全隔绝且无内漏。
核心结论
- 多层平行腔内移植物技术可作为严重成角胸腹主动脉瘤紧急全腔内修复的替代方法。
研究设计与样本
- 本文为个案报道,描述一例76岁男性症状性9 cm IV型胸腹主动脉瘤的紧急全腔内修复。
主要发现
- 患者术后恢复良好,无并发症,5天后出院。
- 术后CT显示内脏和肾动脉支架通畅,动脉瘤完全隔绝,无内漏证据。
临床怎么用
- 对于严重成角且内脏动脉开口邻近的胸腹主动脉瘤,多层平行腔内移植物技术可在紧急情况下实现四血管重建。
局限性
- 本文为个案报道,结论需更大样本验证。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
Total endovascular repair of TAAA using branched, fenestrated stent grafts have been performed with promising midterm results. However, severe angulation of the aorta as well as close proximity of the visceral and renal artery ostia pose a significant technical challenge in designing and implanting branched, fenestrated stent grafts. Parallel grafting offers an alternative technique, allowing an urgent, or emergent total endovascular repair of symptomatic, or ruptured TAAA. We describe a technique of 4-vessel incorporation in a total endovascular repair of TAAA, using multilayered parallel endografting via bilateral femoral and unilateral brachial access. A 76-year-old male with severe chronic obstructive pulmonary disease and coronary artery disease presented with a symptomatic 9 cm extent IV thoracoabdominal aortic aneurysm. The thoracic, and paravisceral segments of his aorta, as well as the iliac arteries were severely angulated, whereas the superior mesenteric and the celiac arteries had a common origin. An urgent total endovascular aortic repair was performed. The aorta and the iliac arteries were straightened by placing stiff wires from bilateral femoral arteries in a "buddy" fashion. In addition, a brachiofemoral "body-floss" wire was established. Over this body-floss wire, thoracic stent grafts were deployed in multiple layers, alternating with parallel branch stents into visceral and renal arteries. Distally, a bifurcated modular stent graft was deployed down to the common iliacs, achieving complete aneurysm exclusion. Patient recovered well without complications and was discharged home in 5 days. Postoperative computed tomography scan showed patent visceral and renal stents and complete exclusion of the aneurysm without evidence of endoleak.
引用
- Han SM, Wartman S, Ham SW, et al. Multilayered Parallel Endografting for Urgent Endovascular Repair of a Severely Angulated Thoracoabdominal Aortic Aneurysm. Ann Vasc Surg. 2017. PMID: 28359794. doi:10.1016/j.avsg.2017.02.007
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。