文献速递主动脉疾病内脏/肾动脉与血管畸形

慢性主动脉夹层中胸主动脉腔内修复支架植入假腔的病例分析

Thoracic Endovascular Aortic Repair into the False Lumen in Chronic Aortic Dissection.
PubMed 文献 · Ann Vasc Surg · 2017-04-06

该文报告2例慢性主动脉夹层伴动脉瘤患者,因真腔呈裂隙状或内脏动脉起源于假腔,选择将支架移植物植入假腔行胸主动脉腔内修复(TEVAR)。第一例以假腔内隔绝动脉瘤为目标,第二例联合肾下腹主动脉开窗以确保分支灌注。结论提示假腔TEVAR可作为替代方案,术前需评估分支血管起源及再灌注必要性。

要点

  • 慢性夹层伴动脉瘤在真腔狭窄或分支起源于假腔时,可考虑假腔TEVAR。
  • 术前必须评估分支血管起源,必要时联合开窗确保内脏/肾动脉灌注。
  • 假腔TEVAR是特定解剖条件下的替代策略,非常规首选。

核心结论

  • 假腔TEVAR可作为慢性主动脉夹层伴动脉瘤的替代治疗方式。
  • 术前评估分支血管起源及可能的分支再灌注需求至关重要。

研究设计与样本

  • 病例报告,共2例慢性主动脉夹层患者。

主要发现

  • 第一例因真腔呈裂隙状,TEVAR目标为从假腔内隔绝动脉瘤。
  • 第二例内脏动脉起源于假腔、肾动脉起源于真腔,行假腔TEVAR并肾下腹主动脉开窗以确保灌注。

临床怎么用

  • 在真腔狭小或分支起源于假腔的慢性夹层病例中,可个体化选择假腔TEVAR。
  • 术前应评估分支血管起源,必要时计划开窗或再灌注。

局限性

  • 仅2例病例报告,证据级别低,结论需更大样本验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Deployment of a stent graft for the treatment of aortic dissections is normally performed in the true lumen. However, in some rare occasions landing in the false lumen may be appropriate. METHODS: We present 2 different cases of chronic aortic dissection, where we opted to land the stent graft into the false lumen to treat the associated aneurysm. RESULTS: For the first case, the goal of thoracic endovascular aortic repair (TEVAR) was to exclude the aneurysm from within the false lumen because of a slit-like true lumen. In the second case, the visceral arteries came off the false lumen, with the renal vessels from the true lumen. False lumen TEVAR was performed, and the infrarenal aorta fenestrated, as to ensure adequate perfusion. CONCLUSIONS: These different clinical scenarios show how false lumen TEVAR for chronic dissections with associated aneurysms can be an alternative treatment approach and highlight the importance of assessing the origin of branch vessels and the possible necessity of reperfusion of these, before TEVAR is performed.

来源:Ann Vasc Surg,查看原文。版权归原作者所有。

引用

  1. Kamman AV, Williams DM, Patel HJ, et al. Thoracic Endovascular Aortic Repair into the False Lumen in Chronic Aortic Dissection. Ann Vasc Surg. 2017. PMID: 28390917. doi:10.1016/j.avsg.2016.11.027

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。