结果显示F-EVAR与Sn-EVAR导致肾分支角度反向改变,仅Sn-EVAR支架末端角度显著增加,这些改变主要发生于术后早期且随访期稳定。中位随访764天,肾支架一期通畅率94.1%。

要点

  • F-EVAR与Sn-EVAR对肾分支角度影响相反,Sn-EVAR增加支架末端角度。
  • 几何改变主要发生于围手术期,随访期无持续显著变化。
  • 中位随访764天,肾支架一期通畅率94.1%,肾功能不全2例。

核心结论

  • F-EVAR与Sn-EVAR导致肾分支角度显著且相反的改变,仅Sn-EVAR引起支架末端角度显著增加。
  • 纵向几何分析提示这些解剖改变主要源于手术本身且在术后随访期保持稳定。

研究设计与样本

  • 术前、术后及随访行CTA,构建主动脉与肾动脉三维几何模型。

主要发现

  • 术前至术后,F-肾分支向上成角,Sn-肾分支向下成角(P<0.05),Sn-肾支架末端角度增加12±15°(P<0.05)。
  • 术后至随访,F-与Sn-肾分支角度均无变化,F-肾支架末端角度增加5±10°(P<0.05)。
  • 术前至术后,全主动脉体积增加5±14%,被排除腔体积增加74±81%,管腔体积减少39±27%(P<0.05)。
  • 术后至随访,全主动脉与被排除腔体积均下降(P<0.05),管腔体积不变。
  • 中位随访764天(范围7-1653天),肾支架一期通畅率94.1%,肾功能不全2例(6.7%)。

临床怎么用

  • 复杂EVAR术后应关注肾动脉分支角度及支架末端角度的早期变化,尤其Sn-EVAR。
  • 随访期几何参数相对稳定,但仍需监测肾支架通畅性及肾功能。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Aneurysm regression and target vessel patency during early and mid-term follow-up may be related to the effect of stent-graft configuration on the anatomy. We quantified geometry and remodeling of the renal arteries and aneurysm following fenestrated (F-) or snorkel/chimney (Sn-) endovascular aneurysm repair (EVAR). METHODS: Twenty-nine patients (mean age, 76.8 ± 7.8 years) treated with F- or Sn-EVAR underwent computed tomography angiography at preop, postop, and follow-up. Three-dimensional geometric models of the aorta and renal arteries were constructed. Renal branch angle was defined relative to the plane orthogonal to the aorta. End-stent angle was defined as the angulation between the stent and native distal artery. Aortic volumes were computed for the whole aorta, lumen, and their difference (excluded lumen). Renal patency, reintervention, early mortality, postoperative renal impairment, and endoleak were reviewed. RESULTS: From preop to postop, F-renal branches angled upward, Sn-renal branches angled downward (P < 0.05), and Sn-renals exhibited increased end-stent angulation (12 ± 15°, P < 0.05). From postop to follow-up, branch angles did not change for either F- or Sn-renals, whereas F-renals exhibited increased end-stent angulation (5 ± 10°, P < 0.05). From preop to postop, whole aortic and excluded lumen volumes increased by 5 ± 14% and 74 ± 81%, whereas lumen volume decreased (39 ± 27%, P < 0.05). From postop to follow-up, whole aortic and excluded lumen volumes decreased similarly (P < 0.05), leaving the lumen volume unchanged. At median follow-up of 764 days (range, 7-1,653), primary renal stent patency was 94.1% and renal impairment occurred in 2 patients (6.7%). CONCLUSIONS: Although F- and Sn-EVAR resulted in significant, and opposite, changes to renal branch angle, only Sn-EVAR resulted in significant end-stent angulation increase. Longitudinal geometric analysis suggests that these anatomic alterations are primarily generated early as a consequence of the procedure itself and, although persistent, they show no evidence of continued significant change during the subsequent postoperative follow-up period.