文献速递主动脉疾病

血管封堵器关闭分支袖套在胸腹主动脉瘤分支腔内修复中的适用性与中期结果

Applicability and midterm results of branch cuff closure with vascular plug in branched endovascular repair for thoracoabdominal aortic aneurysms.
PubMed 文献 · J Vasc Surg · 2017-03-06

16例患者共使用Amplatzer血管封堵器成功关闭17个分支,中位随访19个月,无与封堵袖套相关的内漏或再干预,结论认为该技术可行有效且未伴随不良动脉瘤结局。

要点

  • 血管封堵器关闭未使用分支袖套技术成功率高,围手术期死亡2例。
  • 中位随访19个月,无封堵袖套相关的内漏或再干预。
  • 该技术尤其适用于急性期使用现成支架时关闭多余分支。

核心结论

  • 使用Amplatzer血管封堵器关闭多分支支架未使用的分支袖套可行且有效,未伴随不良动脉瘤结局,尤其在急性期使用现成装置时非常有用。

主要发现

  • 16例患者接受11例择期和5例急诊修复,共成功关闭17个分支。
  • 围手术期死亡2例,中位随访19个月(四分位距11-30个月)。
  • 无与封堵袖套相关的内漏或再干预,2例晚期死亡与动脉瘤无关。
  • 2例患者因胸段迂曲处支架组件分离导致III型内漏伴囊腔扩大而需再干预,与封堵袖套无关。

关键数值与推荐

  • 17个分支中,8个针对术前已闭塞的靶血管,3个为可选分支改用开窗,5个为插管或支架桥接失败后,1个为萎缩肾的肾分支。
  • 4个分支袖套在封堵器释放前用外周覆膜支架延长。
  • 16个分支袖套在术中关闭,剩余1个后期经皮关闭。

临床怎么用

  • 对于b-EVAR术中未使用的分支袖套,可使用Amplatzer血管封堵器关闭,术中或术后经皮均可操作。
  • 封堵袖套前若需要,可先用外周覆膜支架延长分支袖套。

局限性

  • 单中心回顾性研究,样本量小(16例患者),随访时间有限。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: This study assessed the applicability and outcomes of the closure of unused cuffs in branched endovascular aneurysm repair (b-EVAR) of thoracoabdominal aortic aneurysm. METHODS: We reviewed b-EVAR procedures at a tertiary referral center to identify patients who underwent incomplete branching and needed closure of the unused branch cuffs. An electronic database and intraoperative and follow-up imaging studies were reviewed to assess technical applicability and outcomes. RESULTS: Between January 2007 and December 2015, 17 patients underwent incomplete branching during b-EVAR. The unused branch cuff in one patient occluded spontaneously after b-EVAR and was excluded from this analysis. The remaining 16 patients underwent 11 elective and five emergency repairs. Amplatzer Vascular Plugs (St. Jude Medical, Plymouth, Minn) were used to successfully close 17 branches: 8 targeting preoperatively occluded target vessels, 3 optional branches where fenestrations were used instead, 5 after failures of catheterization or stent bridging to target vessels, and 1 renal branch of an atrophic kidney. Four branch cuffs were extended with a peripheral covered stent before plug deployment. Sixteen branch cuffs were closed intraoperatively, and the remaining cuff was closed percutaneously at a later occasion. Perioperative death occurred in two patients. Median follow-up duration was 19 months (interquartile range, 11-30 months). There was no endoleak or reintervention related to the plugged cuffs. Two late deaths occurred not related to the aneurysm. Two patients required reinterventions for type III endoleaks with interval sac expansions caused by aortic stent graft component separation in tortuous thoracic segments not related to the occluded cuffs. CONCLUSIONS: Closure of the branch cuff of multibranched stent graft with Amplatzer Vascular Plug is feasible and effective. It was not associated with adverse aneurysm outcomes, and it is very useful especially when using an off-the-shelf device in the acute setting.

来源:J Vasc Surg,查看原文。版权归原作者所有。

引用

  1. Hongku K, Resch T, Sonesson B, et al. Applicability and midterm results of branch cuff closure with vascular plug in branched endovascular repair for thoracoabdominal aortic aneurysms. J Vasc Surg. 2017. PMID: 28279526. doi:10.1016/j.jvs.2016.12.119

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。