文献速递主动脉疾病

锥形自膨式镍钛支架作为远端裸支架的PETTICOAT技术治疗复杂性急性Stanford B型主动脉夹层

The PETTICOAT Technique for Complicated Acute Stanford Type B Aortic Dissection Using a Tapered Self-Expanding Nitinol Device as Distal Uncovered Stent.
PubMed 文献 · Ann Vasc Surg · 2017-03-07

本文描述使用锥形自膨式镍钛支架E-XL作为远端裸支架的PETTICOAT技术治疗5例复杂性急性B型主动脉夹层。无围术期并发症,随访18-24个月,3例主动脉正向重塑;1例胸腹主动脉瘤患者胸段假腔血栓形成且内脏段真腔扩张;1例Marfan综合征患者因内脏段动脉瘤进展于24个月后行开放手术转换并取出E-XL。结论认为E-XL可用于ABAD,适应不同主动脉直径,径向力促进正向重塑,开放细胞结构允许内脏动脉支架置入,开放转换时可无并发症移除。

要点

  • E-XL锥形自膨式镍钛支架可作为PETTICOAT技术的远端裸支架用于复杂性ABAD。
  • E-XL的大网孔允许通过其置入内脏动脉支架。
  • 随访中多数患者主动脉正向重塑,但需警惕内脏段动脉瘤进展。

核心结论

  • E-XL可成功用于急性B型主动脉夹层,适应不同主动脉直径,径向力促进正向重塑,开放细胞结构允许内脏动脉支架置入,开放转换时可无并发症移除。

研究设计与样本

  • 描述性研究,连续5例复杂性急性B型主动脉夹层患者接受PETTICOAT技术,远端裸支架使用单喇叭口E-XL(Jotec-GmbH)锥形自膨式镍钛支架。

主要发现

  • 1例通过E-XL大网孔成功置入肾动脉支架,无围术期并发症报告。
  • 随访18-24个月,3例出现全主动脉正向重塑。
  • 1例合并胸腹主动脉瘤者18个月CT血管造影显示胸段假腔血栓形成及内脏段主动脉真腔扩张。
  • 1例Marfan综合征者因内脏段动脉瘤进展于24个月后行开放手术转换并取出E-XL。

临床怎么用

  • 对于复杂性急性B型主动脉夹层,可考虑使用E-XL作为远端裸支架行PETTICOAT技术,利用其大网孔保留内脏动脉支架置入通道。
  • 术后需长期影像随访,关注内脏段主动脉瘤进展及是否需要开放转换。

局限性

  • 样本量小(5例),随访时间有限(18-24个月),为描述性研究,缺乏对照。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Provisional Extension To Induce Complete Attachment (PETTICOAT) technique has shown good results in the treatment of acute type B aortic dissections (ABAD). Usually, uncovered tubular stainless steel stents are used to promote distal true lumen reattachment. METHODS: We describe the Petticoat technique using a conic self-expanding nitinol device as distal uncovered stent in five cases of complicated ABAD. We used as distal uncovered stent the single-flared E-XL (Jotec-GmbH). RESULTS: In one case, renal arteries were successfully stented through the large cells of the E-XL. No perioperative complications were reported. During follow-up (18-24 months), positive remodeling of the entire aorta occurred in 3 cases; in 1 case with associated thoracoabdominal aneurysm, false lumen thrombosis at the thoracic level with true lumen expansion at the visceral aorta was detected at the 18-month CT angiogram, and in 1 patient with Marfan syndrome, open surgical conversion with the E-XL explantation was performed after 24 months due to aneurysmal evolution at the visceral level. CONCLUSIONS: The E-XL can be successfully used in ABAD. It adapts to different aortic diameters, and its major radial force promotes successful positive remodeling. The open cell structure allows visceral arteries stenting, and it can be removed without complications during open conversion.

来源:Ann Vasc Surg,查看原文。版权归原作者所有。

引用

  1. Antonello M, Squizzato F, Colacchio C, et al. The PETTICOAT Technique for Complicated Acute Stanford Type B Aortic Dissection Using a Tapered Self-Expanding Nitinol Device as Distal Uncovered Stent. Ann Vasc Surg. 2017. PMID: 28279721. doi:10.1016/j.avsg.2016.10.043