文献速递主动脉疾病

经心尖入路血管内修复胸主动脉病变的病例系列

Transapical Endovascular Repair of Thoracic Aortic Pathology.
PubMed 文献 · Ann Vasc Surg · 2017-03-10

手术全部完成,但3例出现显著主动脉瓣反流,1例死于颈动脉夹层导致的全局性脑缺血,无入路相关并发症。

要点

  • 经心尖入路可作为股髂入路不适合时的替代选择
  • 可能降低严重动脉粥样硬化降主动脉患者的栓塞风险
  • 需关注血流动力学维持、导丝外化及释放时快速起搏等安全问题

核心结论

  • 对于解剖不适合常规逆行入路的患者,经心尖入路TEVAR是潜在的替代方案。
  • 该方法可能降低严重动脉粥样硬化性胸降主动脉患者的栓塞风险。
  • 但需解决血流动力学维持、装置尖端导航的导丝外化及释放时快速起搏等安全问题。

研究设计与样本

  • 5例为主动脉弓部动脉瘤,1例为Stanford A型亚急性主动脉夹层。
  • 经心尖入路指征包括:4例为避免通过严重动脉粥样硬化的胸降主动脉,1例为严重扭曲主动脉,1例为治疗升主动脉夹层病变。

主要发现

  • 所有患者均完成经心尖血管内支架植入。
  • 3例患者在大型鞘管跨过主动脉瓣时出现显著主动脉瓣反流。
  • 1例死于颈动脉旁路及烟囱支架植入后颈动脉夹层导致的全局性脑缺血。
  • 无入路相关并发症。
  • CT显示4例主动脉瘤完全隔绝,1例主动脉夹层患者假腔缩小。

临床怎么用

  • 当股髂入路不适合时,可考虑经心尖入路作为TEVAR的替代选择。
  • 对严重动脉粥样硬化性胸降主动脉患者,经心尖入路可能减少栓塞风险。
  • 术中需注意维持血流动力学、导丝外化辅助装置尖端导航及释放时快速起搏。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Alternative access for thoracic endovascular aortic repair (TEVAR) has been explored for patients with unsuitable femoral and iliac access, but few cases of transapical access have been described. We report our experience with transapical access for various aortic pathologies. METHODS: We reviewed 6 cases undergoing transapical access for endovascular repair of thoracic aortic pathology between December 2013 and August 2015. Five patients had an aortic arch aneurysm and 1 patient presented with Stanford type A subacute aortic dissection. Transapical access was indicated to avoid approach through the severely atherosclerotic thoracic descending aorta in 4 patients and severely kinked aorta in 1 patient and to treat an ascending aortic dissection lesion in 1 patient. RESULTS: Transapical endografting was completed in all patients. Significant aortic valve regurgitation occurred in 3 patients when a large bore sheath was placed across the aortic valve. There was 1 death attributed to global cerebral ischemia due to carotid dissection after carotid bypass and chimney stent-graft insertion. There were no access-related complications. Computed tomography revealed complete exclusion of the aortic aneurysm in 4 patients, and shrinkage of the false lumen in 1 patient with aortic dissection. CONCLUSIONS: Transapical access for TEVAR would be a potential alternative when the anatomy is unfit for routine retrograde approach. This method might have potential benefit of reducing the risk of embolism in patients with severe atherosclerotic thoracic descending aorta. However, certain safety concerns must be addressed, including maintenance of hemodynamics, wire exteriorization for navigation of the device tip, and rapid pacing during deployment.

来源:Ann Vasc Surg,查看原文。版权归原作者所有。

引用

  1. Murakami T, Nishimura S, Hosono M, et al. Transapical Endovascular Repair of Thoracic Aortic Pathology. Ann Vasc Surg. 2017. PMID: 28288887. doi:10.1016/j.avsg.2016.10.054

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。