腹主动脉瘤腔内修复术后主动脉颈直径的变化
该研究回顾2008-2014年86例EVAR患者的CT血管造影,用三维中心线重建测量肾动脉下及下方10mm处主动脉颈直径。中位随访21.9个月,86.0%患者颈径增加,平均增幅从30天的1.3±2.2mm(5.9±9.3%)增至末次随访的3.3±0.6mm(8.9±2.5%),且与器械oversizing程度中度正相关,与器械类型无关。
要点
- EVAR术后多数患者主动脉颈直径随时间增加,末次随访平均增幅约3.3mm。
- 颈径扩张程度与器械oversizing百分比中度正相关,与支架类型无关。
- Ia型内漏患者颈径扩张更明显,需加强影像随访。
核心结论
- EVAR术后主动脉颈直径随时间持续增加,扩张程度与器械oversizing程度相关,但与器械类型无关。
研究设计与样本
- 回顾性分析2008-2014年86例EVAR患者的术前和术后CT血管造影,使用三维中心线重建在正交平面测量主动脉颈直径。
- 中位影像随访21.9个月(范围4-64个月),植入器械包括Cook Zenith 26例、Gore Excluder 26例、Medtronic Endurant 22例、Endologix Powerlink 10例、Trivascular Ovation 2例。
主要发现
- 平均器械oversizing为13.6±11.5%,不同器械类型间无差异(P=0.54)。
- 86.0%患者随访期间主动脉颈直径增加,30天平均增加1.3±2.2mm(5.9±9.3%),末次随访平均增加3.3±0.6mm(8.9±2.5%)。
- 重复测量分析显示随访期间平均颈径扩张显著增加(P<0.001)。
- 不同器械间颈径扩张无显著差异(P=0.233);颈径百分比变化与oversizing程度呈中度正相关(rs=0.41,P<0.001)。
- 2例发生Ia型内漏,其平均颈径扩张更大(8.8±3.3mm vs. 3.35±2.71mm,P=0.041);颈径变化与瘤囊回缩/扩张无关系。
临床怎么用
- EVAR术后应规律影像随访监测主动脉颈直径变化,尤其关注oversizing程度较高者。
- 出现Ia型内漏时需警惕颈径扩张,可能需更密切随访或干预。
局限性
- 回顾性设计,样本量86例,中位随访21.9个月,部分器械亚组例数较少。
- 原文未报告多变量校正、随访丢失及测量者间一致性等细节。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Implications of aortic neck dilatation following endovascular aneurysm repair (EVAR) are unclear. Previous studies are limited to comparisons of individual, early generation devices. We compared aortic neck dilatation among contemporary stent grafts. METHODS: We reviewed preoperative and postoperative computed tomographic angiograms for EVARs performed from 2008-2014. Images were analyzed using 3-dimensional centerline reconstructions. Aortic neck diameter was measured in orthogonal planes at and 10 mm below the lowest renal artery. Device type and main body graft diameter were obtained from operative reports. RESULTS: Eighty-six patients were analyzed with a median radiologic follow-up of 21.9 months (range: 4-64). Stent grants implanted included 26 Cook Zenith, 26 Gore Excluder, 22 Medtronic Endurant, 10 Endologix Powerlink, and 2 Trivascular Ovation devices. Mean device oversizing was 13.6 ± 11.5% and did not vary by device type (P = 0.54). Most patients (86.0%) experienced increases in aortic neck diameter during follow-up, with a mean increase of 1.3 ± 2.2 mm (5.9 ± 9.3%) and 3.3 ± 0.6 mm (8.9 ± 2.5%) at 30 day and latest follow-up scans, respectively. Repeated-measures analysis further demonstrated a significant increase in mean neck dilatation during follow-up (P < 0.001). Neck dilatation was not significantly different across different devices (P = 0.233). However, there was a moderate positive correlation between percent change in neck diameter and degree of oversizing, which was statistically significant (rs = 0.41, P < 0.001). Type Ia endoleak was observed in 2 patients and was associated with greater mean neck dilatation (8.8 ± 3.3 mm vs. 3.35 ± 2.71, P = 0.041). There was no relationship between changes in neck diameter and sac regression/expansion. CONCLUSIONS: Aortic neck diameter increases consistently over time following EVAR. The degree of neck dilatation correlates with degree of device oversize but not with device type.