文献速递主动脉疾病内脏/肾动脉与血管畸形

开窗支架术后肾动脉几何改变及其对肾功能的影响

Geometric Alteration of Renal Arteries After Fenestrated Grafting and the Impact on Renal Function.
PubMed 文献 · Ann Vasc Surg · 2017-02-24

通过术前与术后首次随访CT重建比较肾动脉与支架的夹角(ToA),并检测血清肌酐。结果显示支架置入后双侧肾动脉ToA均显著增大(P<0.05),但术后肾功能损害与支架角度或血管角度变化无关(均P>0.05)。

要点

  • fEVAR术后肾动脉支架置入使肾动脉ToA显著增大(P<0.05)。
  • 术后肾功能损害与支架角度或血管角度变化无关联(均P>0.05)。
  • 开窗支架精准对位对维持支架性能和保护肾功能至关重要。

核心结论

  • 置入的肾动脉支架在开窗支架术后可使肾动脉向头侧成角增大。
  • 术后肾功能损害与支架方向及血管方向变化无关。
  • 精准的开窗对位对维持支架性能和保护肾功能很重要。

研究设计与样本

  • 使用Aquarius工作站重建术前和术后首次随访CT图像,以肠系膜上动脉或腹腔干为参考原点。
  • 比较术前肾动脉与术后支架的开口角(ToA),并测量术前和短期术后血清肌酐。

主要发现

  • 术后首次CT复查肾动脉通畅率为100%。
  • 双侧肾动脉平均ToA在支架置入后均显著增大(P<0.05)。
  • 4例患者(16.0%)中观察到7处支架变形(16.3%),归因于开窗支架向尾侧错位(n=6)或移植物尺寸不准确(n=1)。
  • 术后第1天9例患者(36.0%)和3个月后10例患者(41.7%)出现肾功能损害。
  • 肾功能损害与支架成角或肾动脉角度变化无关(均P>0.05)。

关键数值与推荐

  • 肾功能损害定义为血清肌酐较术前水平升高>30%或>2.0 mg/dL。
  • 支架变形定义为术后CT观察到的支架形态改变,共7处(16.3%)。

临床怎么用

  • fEVAR术中应确保开窗支架精准对位,以减少支架变形和肾功能损害风险。
  • 术后需监测血清肌酐以评估肾功能,即使支架角度变化与肾功能损害无关联。

局限性

  • 仅评估短期术后肾功能和支架形态变化。
  • 单中心回顾性设计可能限制结论的普遍性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: This study aims to investigate the degree of geometric change on renal arteries and its impact on renal function after fenestrated endovascular aortic repair (fEVAR). METHODS: Twenty-five patients with fEVAR were included. There were 47 renal arteries target vessels, and 43 of these (22 left and 21 right vessels) stented successfully. Their preoperative and first postoperative follow-up computed tomography (CT) images were reconstructed using the Aquarius workstation (TeraRecon, San Mateo, CA, USA). The superior mesenteric artery (SMA) or celiac axis (if SMA was stented) was appointed as reference origin. The longitudinal orientation of a renal artery or a stent was represented by a takeoff angle (ToA) between the renal artery or stent and the distal abdominal aorta. The postoperative stent ToAs were compared with those of preoperative renal arteries. Preoperative and short-term postoperative serum creatinine levels were measured. Renal function impairment was indicated as a >30% or >2.0 mg/dL rise in serum creatinine compared to the preoperative level. The relationship between postoperative renal function impairment and the stent orientation or geometric changes in renal arteries was correlated. RESULTS: The patency rate of renal arteries was 100% at the first postoperative CT review. The average ToAs of both renal arteries were significantly enlarged after stenting (P < 0.05). Seven stent deformations (16.3%) in four patients (16.0%) were observed. They were attributed to caudal misalignment of the fenestrated stent graft (n = 6) or inaccurate graft sizing (n = 1). There was no stent fracture or target vessel loss. Postoperatively, nine patients (36.0%) at day 1 and 10 patients (41.7%) after 3 months suffered the renal function impairment. This was found not to be associated with the stent angulation or angular change of the renal arteries (both P > 0.05). The three patients with stent deformation due to misalignment suffered postoperative renal function impairment and continuing deterioration in renal function. CONCLUSIONS: Implanted renal stents could angulate renal arteries more cephalad after fenestrated stenting. Postoperative renal function impairment was not associated with the stent orientation and changes in vessel orientation. Accurate fenestrated alignment is important to maintain stent performance and preserve renal function.

来源:Ann Vasc Surg,查看原文。版权归原作者所有。

引用

  1. Ou J, Chan YC, Chan CY, et al. Geometric Alteration of Renal Arteries After Fenestrated Grafting and the Impact on Renal Function. Ann Vasc Surg. 2017. PMID: 28238921. doi:10.1016/j.avsg.2016.09.036

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。