文献速递颈动脉与弓上血管血液透析通路

锁骨下动脉双功超声流速标准验证:分级狭窄严重程度

Validation of subclavian duplex velocity criteria to grade severity of subclavian artery stenosis.
PubMed 文献 · J Vasc Surg · 2017-02-17

本研究回顾性分析177例患者共268条动脉,对比锁骨下动脉双功超声流速与血管造影测量的狭窄程度。

要点

  • 收缩期峰值流速>240 cm/s预测>70%锁骨下动脉狭窄的敏感度90.9%、特异度82.5%。
  • 曲线下面积0.94(95%CI 0.91–0.97),提示流速标准判别能力良好。
  • 椎动脉反向血流的动脉被排除分析,临床应用时需注意。

核心结论

  • 在已知或怀疑大血管病变的患者中,锁骨下动脉流速超过240 cm/s似乎可预测显著锁骨下动脉狭窄。

研究设计与样本

  • 回顾性研究,纳入1999年5月至2013年7月期间接受锁骨下动脉双功超声和血管造影的疑似锁骨下动脉狭窄患者及便利样本的颈动脉患者。

主要发现

  • 245条动脉的平均收缩期峰值流速为212.6 ± 110.7 cm/s,范围45–626 cm/s。
  • 平均狭窄程度为25.8% ± 28.2%,范围0%至100%。
  • 受试者工作特征分析显示,>240 cm/s是预测>70%狭窄的最佳 cutoff 值,曲线下面积0.94(95%CI 0.91–0.97)。
  • 预测>70%狭窄的敏感度和特异度分别为90.9%和82.5%。

关键数值与推荐

  • 推荐以收缩期峰值流速>240 cm/s作为预测>70%锁骨下动脉狭窄的超声流速标准。

临床怎么用

  • 对疑似锁骨下动脉狭窄患者,双功超声测得收缩期峰值流速>240 cm/s时提示存在>70%显著狭窄,可据此进一步评估或干预。

局限性

  • 研究使用便利样本,当前提出的 cutoff 值可能需要针对其他人群进行调整。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Validation of subclavian duplex ultrasound velocity criteria (SDUS VC) to grade the severity of subclavian artery stenosis has not been established or systematically studied. Currently, there is a paucity of published literature and lack of practitioner consensus for how subclavian duplex velocity findings should be interpreted in patients with subclavian artery stenosis. OBJECTIVE: The objective of the present study was to validate SDUS measurements using subclavian conventional or computed tomography angiogram (subclavian angiogram [SA])-derived measurements. Secondary objectives included measuring the correlation between SDUS peak systolic velocities and SA measurements, and to determine the optimal cutoff value for predicting significant stenosis (>70%). METHODS: This is a retrospective review of all patients with suspected subclavian artery stenosis and a convenience sample of carotid artery patients who underwent SDUS and SA from May 1999 to July 2013. SA reference vessel and intralesion minimal lumen diameters were measured and compared with SDUS velocities obtained within 3 months of the imaging study. Percent stenosis was calculated using the North American Symptomatic Carotid Endarterectomy Trial method for detecting stenosis in a sufficiently large cohort. Receiver operating characteristic curves was generated for SDUS VC to predict >70% stenosis. Velocity cutoff points were determined with equal weighting of sensitivity and specificity. RESULTS: We examined 268 arteries for 177 patients. The majority of the arteries were for female patients (52.5%) with a mean age of 66.7 ± 11.1 years. Twenty-three arteries had retrograde vertebral artery flow and excluded from further analysis. For the remaining 245 arteries, the average peak systolic velocity was 212.6 ± 110.7 cm/s, with a range of 45-626 cm/s. Average stenosis was 25.8% ± 28.2%, with a range of 0% to 100%. Following receiver operating characteristic analysis, we found a cutoff value of >240 cm/s to be most predictive of >70%. Area under the curve was 0.94 with 95% confidence intervals of 0.91 to 0.97. The sensitivity and specificity for predicting >70% stenosis was 90.9 and 82.5%, respectively. CONCLUSIONS: In patients with known or suspected disease involving the great vessels, a subclavian artery flow velocity exceeding 240 cm/s seems to be predictive of significant subclavian stenosis. Thus, we propose new SDUS VC, for predicting subclavian artery stenosis. However, because of the use of a convenience sample, it is possible that the current proposed cutoff point might need to be adjusted for other populations.

来源:J Vasc Surg,查看原文。版权归原作者所有。

引用

  1. Mousa AY, Morkous R, Broce M, et al. Validation of subclavian duplex velocity criteria to grade severity of subclavian artery stenosis. J Vasc Surg. 2017. PMID: 28222983. doi:10.1016/j.jvs.2016.12.098

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。