文献速递主动脉疾病

彩色编码定量数字减影血管造影预测EVAR后即刻I型及III型内漏结局

Application of color-coded quantitative digital subtraction angiography in predicting the outcomes of immediate type I and type III endoleaks.
PubMed 文献 · J Vasc Surg · 2017-02-16

随访至少6个月后发现,发生内漏相关不良事件的患者TTP显著更低,且混合型内漏风险更高;TTP≤5秒和混合型内漏是内漏相关不良事件的潜在预测因素。

要点

  • CQDSA可定量评估EVAR后即刻I型或III型内漏的血流动力学。
  • TTP≤5秒预测内漏相关不良事件的敏感性为91.67%,特异性为69.57%。
  • 混合型内漏患者发生内漏相关不良事件的风险显著高于单纯型内漏。

核心结论

  • CQDSA有助于预测EVAR后即刻I型或III型内漏的结局,TTP≤5秒和混合型内漏是内漏相关不良事件的潜在预测因素。

主要发现

  • 随访至少6个月后,12例发生内漏相关不良事件,23例未发生,中位随访时间24.0个月。
  • 发生内漏相关不良事件的患者TTP显著更低(P = .002)。
  • 混合型内漏患者发生内漏相关不良事件的风险显著高于单纯型内漏患者(P = .003)。

关键数值与推荐

  • TTP≤5秒达到敏感性和特异性之和最大,敏感性91.67%,特异性69.57%。
  • 逻辑回归分析证实TTP≤5秒(P = .016)和混合型内漏(P = .044)与内漏相关不良事件风险升高相关。

临床怎么用

  • CQDSA可对内漏进行客观评估,为即刻再干预或保守治疗提供参考。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: Immediate type I and type III endoleaks after endovascular aneurysm repair (EVAR) could be persistent or temporary. Reintervention is necessary for persistent ones. Color-coded quantitative digital subtraction angiography (CQDSA) could provide a quantitative evaluation of the endoleak hemodynamics. We aimed to use CQDSA to quantify immediate type I and type III endoleaks after EVAR and to find a practical way to predict their outcomes. METHODS: Between January 2012 and December 2014, 485 consecutive patients with abdominal aortic aneurysms underwent EVAR at our institution. Thirty-five patients (31 men, four women) with slight immediate type I and type III endoleaks after EVAR were recruited in the prospective observational nested case-control study. After at least 6 months of follow-up, these patients were divided into two groups based on endoleak-related adverse events. Their final intraprocedure DSA images were collected and converted into a single polychromatic image for CQDSA measurements. The parameter time to peak (TTP) of the selected regions of interest in the endoleak area and a reference area at the same latitude within the stent graft were derived from the time-intensity curve. A receiver operating characteristic curve was generated to test the ability of TTP to predict endoleak-related adverse events and to identify the optimal cutoff value. RESULTS: Finally, two groups were identified: 12 patients with endoleak-related adverse events and 23 patients without endoleak-related adverse events. Median follow-up time for all patients was 24.0 months. Age, gender, and comorbidity were similar in these two groups. TTP was significantly lower in patients with endoleak-related adverse events (P = .002). The risk of endoleak-related adverse events was significantly higher in patients with mixed-type endoleak than in those with simple-type endoleak (P = .003). According to the receiver operating characteristic curves, TTP ≤5 seconds reached the maximal sum of sensitivity and specificity (sensitivity, 91.67%; specificity, 69.57%). Logistic regression analysis confirmed that TTP ≤5 seconds (P = .016) and mixed-type endoleak (P = .044) were associated with higher risk of endoleak-related adverse events. CONCLUSIONS: CQDSA could help predict the outcomes of immediate type I or type III endoleaks after EVAR. TTP ≤5 seconds and mixed-type endoleak were two potential predictors of endoleak-related adverse events. This approach may offer an objective assessment of such immediate endoleaks and reference for immediate reintervention or conservative therapy.

来源:J Vasc Surg,查看原文。版权归原作者所有。

引用

  1. Zhou M, Su Z, Shi Z, et al. Application of color-coded quantitative digital subtraction angiography in predicting the outcomes of immediate type I and type III endoleaks. J Vasc Surg. 2017. PMID: 28216350. doi:10.1016/j.jvs.2016.11.048

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。