文献速递慢性静脉疾病

辅助性数字减影静脉造影在大隐静脉功能不全治疗中的应用价值

Utility of Adjunctive Digital Subtraction Venography for the Treatment of Saphenous Vein Insufficiency.
PubMed 文献 · J Endovasc Ther · 2017-01-06

结果显示66%患者存在目标静脉异常,44%需血管内操作才能完成消融,17%无法在无辅助透视引导下完成。静脉造影识别异常的敏感性远高于术前超声(64% vs 11%)。

要点

  • 辅助性静脉造影可发现超声漏诊的静脉解剖异常,敏感性仅17.1%。
  • 44%患者需额外血管内操作,17%无法脱离透视引导完成消融。
  • 对复杂解剖患者,静脉造影有助于提高消融完全率。

核心结论

  • 静脉造影是超声的有价值补充,有助于在特定复杂解剖患者中实现功能不全大隐静脉的完全消融。

主要发现

  • 共完成542次静脉造影(每肢体2.0次),平均持续时间4.9±9.1分钟(范围1-48分钟)。
  • 132例(66%)患者靶静脉内存在异常或变异;88例(44%)需要血管内操作才能成功完成消融;34例(17%)无法在无辅助透视引导下完成。
  • 与术前静脉超声报告相比,静脉造影发现异常的患者为123例(64%,193处异常),而超声仅发现21例(11%,23处异常)。
  • 超声的敏感性为17.1%,特异性100%,阳性预测值100%,阴性预测值40.7%。

临床怎么用

  • 在复杂解剖的静脉消融病例中,可考虑在超声基础上加用辅助性静脉造影和透视引导,以识别异常并指导操作,提高消融完全率。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To report the use of adjunctive venography for the treatment of superficial venous reflux. METHODS: Two hundred consecutive patients (mean age 60.9 years, range 33-86; 128 women) with chronic venous disease underwent saphenous or perforator vein ablation in 268 limbs (305 venous trunks) guided by adjunctive venography and fluoroscopy in addition to ultrasound between October 2010 and May 2016. Intraprocedural venograms were independently evaluated by 2 vascular specialists to identify the presence of venous anomalies and the need for fluoroscopy-guided maneuvers to successfully complete venous ablation. Intraprocedural venography results were compared with preoperative venous duplex scan reports to ascertain if the duplex study could be of value in identifying preoperatively any anatomical variants that may pose a technical challenge to the operator. RESULTS: In this cohort, 542 venograms (2.0/limb) were performed with a mean duration of 4.9±9.1 minutes (range 1-48). Two thirds of patients (132, 66%) had anomalies or abnormalities within the target vein; more than a third (88, 44%) required an endovascular maneuver to successfully complete the ablation and 17% (34) of cases were impossible to complete without adjunctive fluoroscopic guidance. Per-patient comparison of intraprocedural venography with preoperative venous duplex reports identified 21 (11%) patients with abnormalities detected on ultrasound (23 anomalies) compared with 123 (64%) on venography (193 anomalies). This gave ultrasound a 17.1% sensitivity, 100% specificity and positive predictive value, and 40.7% negative predictive value. CONCLUSION: Venography is a valuable addition to ultrasound to facilitate complete ablation of insufficient saphenous veins in selected patients with complex anatomy.

来源:J Endovasc Ther,查看原文。版权归原作者所有。

引用

  1. Varcoe RL, Thomas SD, Bourke V, et al. Utility of Adjunctive Digital Subtraction Venography for the Treatment of Saphenous Vein Insufficiency. J Endovasc Ther. 2017. PMID: 28056580. doi:10.1177/1526602816686734

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。