文献速递主动脉疾病

Zenith即用型p-branch支架在既往烟囱技术治疗的近肾腹主动脉瘤中的解剖适用性

Anatomical Suitability of the Zenith Off-the-Shelf (p-Branch) Endograft in Juxtarenal Aortic Aneurysms Previously Treated Using the Chimney Technique.
PubMed 文献 · J Endovasc Ther · 2017-01-01

该回顾性研究纳入50例既往接受烟囱技术腔内修复的近/旁肾腹主动脉瘤患者,基于三维血管工作站按Zenith p-branch研究性器械豁免方案评估解剖适用性。主要适用率为54%(n=27),两种配置各适用18例(36%);若辅以入路血管附加干预,次要适用率可达64%(n=32)。

要点

  • Zenith p-branch在既往chEVAR患者中主要解剖适用率约54%。
  • A、B两种配置各适用36%患者,主要限制为SMA-LRA间距和LRA时钟位。
  • 辅以入路血管干预后次要适用率可提升至64%。

核心结论

  • 在既往接受chEVAR的近/旁肾腹主动脉瘤患者中,Zenith p-branch系统约对半数患者解剖适用,辅以入路血管干预后可提升至约三分之二。

研究设计与样本

  • 回顾性研究,纳入2012年1月至2014年12月50例(平均年龄79岁,45例男性)既往以chEVAR治疗的近/旁肾腹主动脉瘤患者,基于高分辨率CTA和临床数据评估。

主要发现

  • Zenith p-branch主要解剖适用率为54%(n=27),每种配置各适用18例(36%)。
  • 主要解剖限制包括左肾动脉时钟位(n=7,14%)、SMA与左肾动脉间距(A配置n=16,32%;B配置n=16,32%)以及髂动脉显著狭窄或钙化。
  • 采用入路血管附加干预后,次要适用率达64%(n=32)。

关键数值与推荐

  • 主要适用性依据Zenith p-branch研究性器械豁免方案在三维血管工作站评估。
  • 次要适用性定义为需附加干预以克服入路血管不良解剖条件。
  • Zenith p-branch有A、B两种配置,主要差异为肠系膜上动脉与肾动脉开窗间距。

临床怎么用

  • 对既往chEVAR的近/旁肾腹主动脉瘤患者,可术前按p-branch方案评估解剖适用性。
  • 入路血管不良解剖条件可考虑附加干预以提高适用性。

局限性

  • 回顾性设计,样本量50例,单中心经验。
  • 结论需前瞻性临床研究进一步验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To examine the suitability of the Zenith off-the-shelf (p-branch) endograft in patients with juxta- or pararenal abdominal aortic aneurysms (J/PRAA) previously treated with endovascular aneurysm repair incorporating the chimney technique (chEVAR). METHODS: Between January 2012 and December 2014, high-resolution computed tomography angiograms and clinical data from 50 patients (mean age 79 years; 45 men) with J/PRAAs treated with chEVAR were retrospectively reviewed. Primary anatomical suitability was evaluated according to the Investigational Device Exemption protocol for the Zenith p-branch endograft in a dedicated 3-dimensional vascular workstation. Secondary suitability was defined as any additional intervention needed to overcome adverse anatomical conditions at the access vessels. The Zenith p-branch endograft is available in 2 configurations (A and B), with the main difference being the distance between the superior mesenteric artery (SMA) and the renal fenestrations. RESULTS: The p-branch endograft showed a primary suitability of 54% (n=27). Each configuration was suitable in 18 (36%) patients. Main anatomical limitations were the clock position of the left renal artery (LRA; n=7, 14%), the distance between the SMA and LRA (A: n=16, 32%; B: n=16, 32%), and significantly narrowed or calcified iliac arteries. If additional interventions at the access vessels were employed, a secondary suitability of 64% (n=32) could be achieved. CONCLUSION: In this specific group of patients treated with chEVAR, the Zenith p-branch system would be suitable in about half of the patients, which could be raised to two-thirds with ancillary access vessel procedures. A prospective clinical study is warranted to evaluate these results.

来源:J Endovasc Ther,查看原文。版权归原作者所有。

引用

  1. Schroeder M, Donas KP, Stavroulakis K, et al. Anatomical Suitability of the Zenith Off-the-Shelf (p-Branch) Endograft in Juxtarenal Aortic Aneurysms Previously Treated Using the Chimney Technique. J Endovasc Ther. 2017. PMID: 28042763. doi:10.1177/1526602816684628

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。