文献速递主动脉疾病

开窗与分支支架移植物治疗复杂主动脉瘤的单中心早期经验

Fenestrated and Branched Stent Grafting in Complex Aneurysmatic Aortic Disease: A Single-Center Early Experience.
PubMed 文献 · Ann Vasc Surg · 2016-11-24

BACKGROUND: The aim of this study is to present our early experience and highlight the technical difficulties associated with the use of fenestrated and branched stent grafts to treat patients with juxtarenal abdominal aortic aneurysm (AAA), pararenal AAA, and thoracoabdominal ao…

要点

  • 开窗/分支支架可用于合并严重合并症、不适合开放手术的复杂主动脉瘤患者。
  • 靶血管成功率高,短期死亡率低,但需个体化克服技术挑战。
  • 内漏可经腔内处理,随访期间无死亡或重大并发症。

核心结论

  • 开窗与分支腔内支架移植物可用于合并显著合并症患者的近肾性腹主动脉瘤、肾旁性腹主动脉瘤及胸腹主动脉瘤修复。
  • 由于每例患者复杂主动脉病理独特,需克服若干技术挑战。

研究设计与样本

  • 单中心前瞻性维护数据库查询,纳入接受分支或开窗支架移植物治疗的腹主动脉瘤或胸腹主动脉瘤患者。
  • 共8例患者接受开窗或分支支架修复,评估修复指征、妨碍开放手术的合并症、技术挑战、手术死亡率、并发症及再干预率。

主要发现

  • 所有患者均为近肾主动脉、肾旁主动脉及胸腹主动脉瘤样变,不适合标准腔内技术。
  • 2例有既往主动脉修复史,分别为支架移植物移位失败和开放修复后旧手术直管移植物。
  • 1例为III型胸腹主动脉瘤,1例为夹层后I型胸腹主动脉瘤。
  • 靶血管成功率为96.4%(27/28),平均住院时间6.0天(范围3-21)。

临床怎么用

  • 对于合并显著合并症、不适合开放手术的近肾性、肾旁性腹主动脉瘤及胸腹主动脉瘤患者,可考虑开窗或分支支架腔内修复。
  • 需认识每例患者复杂主动脉病理的独特性,并准备克服相应技术挑战。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The aim of this study is to present our early experience and highlight the technical difficulties associated with the use of fenestrated and branched stent grafts to treat patients with juxtarenal abdominal aortic aneurysm (AAA), pararenal AAA, and thoracoabdominal aortic aneurysms (TAAAs). METHODS: A prospectively held database maintained at our department was queried for patients who have undergone branched and fenestrated stent grafting for AAA or TAAA treatment. Indication for repair, comorbidity precluding open repair, technical challenges associated with the repair, as well as operative mortality, morbidity, and reintervention rate were evaluated. RESULTS: A total of 8 patients underwent repair with a fenestrated or branched stent graft. All patients had aneurysmal degeneration of the juxtarenal aorta, pararenal aorta, and thoracoabdominal aorta not suitable to standard endovascular techniques. Two patients had a prior aortic repair, a failed migrated stent graft, and an old surgical tube graft after an open repair. One patient had a type III TAAA and 1 patient had a postdissection TAAA type I. For all patients, target vessel success rate was 96.4% (27/28) and mean hospital stay was 6.0 days (range 3-21). Thirty-day and 1-year mortality were 0%. Mean follow-up was 23 months (range 7-45). Two endoleaks occurred, 1 type III and 1 type II, which were treated endovascularly. No death or major complication occurred during follow-up. CONCLUSIONS: Fenestrated and branched endovascular stent grafts can be used to repair juxtarenal AAA, pararenal AAA, and TAAA in patients with significant comorbidities. However, several technical challenges have to be overcome due to the unique complex aortic pathology of each patient.

来源:Ann Vasc Surg,查看原文。版权归原作者所有。

引用

  1. Vourliotakis GD, Tzilalis VD, Theodoridis PG, et al. Fenestrated and Branched Stent Grafting in Complex Aneurysmatic Aortic Disease: A Single-Center Early Experience. Ann Vasc Surg. 2016. PMID: 27890847. doi:10.1016/j.avsg.2016.07.078

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。