TEVAR中空气栓塞:二氧化碳冲洗减少胸主动脉支架释放气体量

Air Embolism During TEVAR: Carbon Dioxide Flushing Decreases the Amount of Gas Released from Thoracic Stent-Grafts During Deployment.
PubMed 文献 · J Endovasc Ther · 2016-10-26

该实验台研究将20个Zenith胸主动脉支架分为两组,分别用60 mL生理盐水冲洗或二氧化碳冲洗5分钟后再用60 mL生理盐水冲洗,测量释放气体量。结果显示二氧化碳冲洗组平均释放气体量显著低于生理盐水组(0.79 vs 0.51 mL,p=0.005)。结论认为二氧化碳冲洗可减少支架释放时气体释放,建议作为主动脉支架标准冲洗技术。

要点

  • 胸主动脉支架按说明书冲洗后释放时仍会释放气体。
  • 二氧化碳冲洗组释放气体量显著低于生理盐水组(0.79 vs 0.51 mL,p=0.005)。
  • 建议将二氧化碳冲洗作为主动脉支架标准冲洗技术以减少空气栓塞风险。

核心结论

  • 二氧化碳冲洗胸主动脉支架可显著减少释放时气体量,建议作为标准冲洗技术。

研究设计与样本

  • 实验台研究,20个Zenith胸主动脉支架分为两组,每组10个。

主要发现

  • 两组支架释放时均释放气体,二氧化碳冲洗组平均释放气体量显著低于生理盐水组(0.79 vs 0.51 mL,p=0.005)。

关键数值与推荐

  • 生理盐水组冲洗60 mL;二氧化碳组冲洗5分钟后再用60 mL生理盐水冲洗。

临床怎么用

  • 胸主动脉支架置入前可考虑额外使用二氧化碳冲洗以减少空气栓塞和卒中风险,尤其近端主动脉段。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To investigate the amount of gas released from Zenith thoracic stent-grafts using standard saline flushing vs the carbon dioxide flushing technique. METHODS: In an experimental bench setting, 20 thoracic stent-grafts were separated into 2 groups of 10 endografts. One group of grafts was flushed with 60 mL saline and the other group was flushed with carbon dioxide for 5 minutes followed by 60 mL saline. All grafts were deployed into a water-filled container with a curved plastic pipe; the deployment was recorded and released gas was measured using a calibrated setup. RESULTS: Gas was released from all grafts in both study groups during endograft deployment. The average amount of released gas per graft was significantly lower in the study group with carbon dioxide flushing (0.79 vs 0.51 mL, p=0.005). CONCLUSION: Thoracic endografts release significant amounts of air during deployment if flushed according to the instructions for use. Application of carbon dioxide for the flushing of thoracic stent-grafts prior to standard saline flush significantly reduces the amount of gas released during deployment. The additional use of carbon dioxide should be considered as a standard flush technique for aortic stent-grafts, especially in those implanted in proximal aortic segments, to reduce the risk of air embolism and stroke.

来源:J Endovasc Ther,查看原文。版权归原作者所有。