文献速递静脉血栓栓塞

使用FlowTriever和ClotTriever系统回收血栓性下腔静脉滤器及机械血栓切除术,并以ClotTriever作为栓塞保护

Retrieval of Thrombosed Inferior Vena Cava Filter and Mechanical Thrombectomy of Associated Caval Thrombosis Using FlowTriever and ClotTriever Systems With the ClotTriever as Embolic Protection.
PubMed 文献 · J Endovasc Ther · 2026-10-17

一例55岁中国男性抗磷脂综合征患者,下腔静脉滤器置入后发生滤器及下腔静脉血栓,使用ClotTriever和FlowTriever装置行腔内机械血栓切除术并回收血栓性滤器,以ClotTriever BOLD作为近端栓塞保护,手术成功且无肺栓塞症状。

要点

  • ClotTriever BOLD可临时用作近端栓塞保护,在缺乏ProTrieve鞘等专用装置时辅助回收血栓性滤器。
  • 对于滤器相关下腔静脉血栓,机械血栓切除联合滤器回收可行,需评估下腔静脉尺寸是否合适。
  • 术后无肺栓塞症状,提示该操作策略可能安全,但需进一步验证。

核心结论

  • 使用ClotTriever和FlowTriever系统可成功行下腔静脉及髂股静脉机械血栓切除并回收血栓性滤器,以ClotTriever BOLD作为近端栓塞保护未发生肺栓塞症状。

研究设计与样本

  • 单例病例报告:55岁中国男性,抗磷脂综合征,下腔静脉滤器置入后发生滤器及下腔静脉血栓,行腔内机械血栓切除和滤器回收。

主要发现

  • 患者术后症状改善,无肺栓塞症状,手术成功。
  • CT静脉造影显示血栓从下腔静脉滤器延伸至右膝下静脉。

临床怎么用

  • 在缺乏ProTrieve鞘等专用栓塞保护装置时,可考虑将ClotTriever BOLD与大口径逆行鞘配合用作近端栓塞保护,以回收血栓性下腔静脉滤器,但需患者下腔静脉尺寸合适。

局限性

  • 单例病例报告,结果不能推广;技术可行性需更多研究验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

A 55-year-old Chinese male with anti-phospholipid syndrome presented with left lower limb deep venous thrombosis (DVT) on warfarin and had an inferior vena cava filter (IVCF) implanted before a radical resection of a perineal sarcoma. The inferior vena cava (IVC) filter removal was attempted 2 weeks after the surgery, but thrombus was found at the filter. It was decided to leave the filter and to continue with anticoagulation. He presented with progressive right lower limb swelling, erythema and pain, with a CT venogram showing caval thrombosis extending from the IVC filter to the right below-knee veins. In view of worsening symptoms, endovenous mechanical thrombectomy of the IVC and iliofemoral veins, as well as caval filter removal, was performed using the ClotTriever and FlowTriever devices (Inari Medical, US). The ClotTriever itself was then placed alongside a 16Fr internal jugular vein (IJV) sheath to remove the thrombosed filter. The FlowTriever disc was next deployed from jugular access as proximal embolic protection during the thrombectomy procedure. The procedure was successful with no symptoms of pulmonary embolism (PE). This report illustrates the alternative use of the ClotTriever BOLD as an intra-operative proximal embolic protection in the absence of alternative devices like a ProTrieve sheath, during caval thrombectomy and removal for caval thrombosis secondary to an IVC filter.Clinical ImpactThe ClotTriever BOLD catheter, deployed alongside a large retrograde sheath may be considered as an proximal embolic protection for removing thrombosed IVCFs, where there is patient with a suitably sized IVC and when alternative and appropriate devices are unavailable.

来源:J Endovasc Ther,查看原文。版权归原作者所有。

引用

  1. So SE, Chan DYS, Tam JSC, et al. Retrieval of Thrombosed Inferior Vena Cava Filter and Mechanical Thrombectomy of Associated Caval Thrombosis Using FlowTriever and ClotTriever Systems With the ClotTriever as Embolic Protection. J Endovasc Ther. 2026. PMID: 42888959. doi:10.1177/15266028261497455

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。